FQ_ADJACENT_CP_NAME
Required? | No |
Keyword Type | String |
Field Length | 3–17 |
Multiples Allowed? | No, only one for each LINK_STATION keyword |
The FQ_ADJACENT_CP_NAME parameter specifies the fully qualified control point (CP) name that is directly connected to your workstation across this link.
The fully qualified CP name is a 17-byte character string. The fully qualified CP name consists of two parts: the network name and the CP name, concatenated with a period. The network name is a 1- to 8-byte SNA Type A character string. The CP name is a 1- to 8-byte SNA Type A character string. The fully qualified CP name is also known as the network qualified CP name.
This parameter is optional.
- This field is only relevant for links to APPN nodes and is otherwise ignored.
- For links to APPN nodes, do not specify this parameter
unless you specify the TG_NUMBER parameter as a number in the range
1–20 or you specify the ADJACENT_NODE_TYPE parameter as SUBAREA_LEN.
If you specify this parameter, it is checked against the name received from the adjacent node during XID exchange, unless the ADJACENT_NODE_TYPE parameter is specified as SUBAREA_LEN, in which case it is used to identify the adjacent node.