EFFECTIVE_CAPACITY

Required? No
Keyword Type Unsigned number
Default Use PORT setting of EFFECTIVE_CAPACITY.
Multiples Allowed? No, only one for each LINK_STATION keyword
The EFFECTIVE_CAPACITY parameter specifies the units of effective capacity for this link station. The value is encoded as a 1-byte floating-point number, represented by the following formula:
0.1 mmm * 2 eeeee

where the bit representation of the byte is eeeeemmm. Each unit of effective capacity is equal to 300 bits per second.

This parameter is optional.