ACCEPT_INCOMING_CALLS

Required? Yes
Keyword Type Boolean
Default 0
Multiples Allowed? No, only one for each PORT_SDLC_SPECIFIC_DATA parameter
The ACCEPT_INCOMING_CALLS parameter specifies whether Communications Server or Personal Communications is able to accept calls from other computers. Valid values are:
0
The product is not able to accept calls from other computers.
1
The product is able to accept calls from other computers.

This parameter is required. The default is 0.

If you allow the product to accept incoming calls through a COM port, it has exclusive use of the port when you start the configuration. If you want another program to use this port, you must stop Communications Server or Personal Communications to stop the COM port device. (Merely closing the session using the port is not enough, because that does not stop the COM port devices.)