Printing reports

  1. Click Reports on the ITOMweb home page and then locate the reports to be printed.

    Tip: To find the report that you want to print, you can click the Search button and specify search criteria.

  2. Print the report:
    • From the Report Listing results page, click the Action icon in the far left column, next to the name of the report that you want to print, and select Print from the drop-down list of actions.
    • Alternately, you can click the link in the TIMESTAMP column to view the report, and mark specific pages to be printed. The Print button is on the top right corner of the Report Viewing page.
  3. Specify values in the following fields, as needed, to control how the report is printed and to include additional information in the output.
    All fields are optional. If you specify no values (if you leave the fields blank or accept the default values), the report is printed using the default values that have been defined for printing JES output on your system.
    Name
    Type the name of the recipient (a person or location). This value can be up to 60 characters in length. It can be composed of alphanumeric characters, national characters ($, #, @), and various special characters. If an invalid character is specified in this field, the field text is highlighted in red and a message box appears indicating the name of the field in error along with a list of valid characters.
    Title
    Type a title to include on the separator pages for the printed report (for example, "Annual Report"). This value can be up to 60 characters in length. It can be composed of alphanumeric characters, national characters ($, #, @), and various special characters. If an invalid character is specified in this field, the field text is highlighted in red and a message box appears indicating the name of the field in error along with a list of valid characters.
    Dept
    Type the name of the recipient's department. This value can be up to 60 characters in length. It can be composed of alphanumeric characters, national characters ($, #, @), and various special characters. If an invalid character is specified in this field, the field text is highlighted in red and a message box appears indicating the name of the field in error along with a list of valid characters.
    Room
    Type the identifier for the room in which the recipient is located. This value can be up to 60 characters in length. It can be composed of alphanumeric characters, national characters ($, #, @), and various special characters. If an invalid character is specified in this field, the field text is highlighted in red and a message box appears indicating the name of the field in error along with a list of valid characters.
    Building
    Type the identifier for the building in which the recipient is located. This value can be up to 60 characters in length. It can be composed of alphanumeric characters, national characters ($, #, @), and various special characters. If an invalid character is specified in this field, the field text is highlighted in red and a message box appears indicating the name of the field in error along with a list of valid characters.
    Address
    Type the recipient's mailing address. This value can be up to 60 characters in length. It can be composed of alphanumeric characters, national characters ($, #, @), and various special characters. If an invalid character is specified in this field, the field text is highlighted in red and a message box appears indicating the name of the field in error along with a list of valid characters.
    Class
    Type the name of the SYSOUT class for the report data set. This value must be composed of one alphanumeric character (a letter from A through Z or a number from 0 through 9).
    Dest
    Type the name of the destination for the report data set. A destination can be a remote or local terminal, a node, a node and remote workstation, a local device or group of devices, or a node and user ID.
    Pagedef
    Type the name of a member on the z/OS® system that contains statements to direct the Print Services Facility (PSF) how to print a data set on a page-mode printer. The data set can hold SYSOUT from the spool or be allocated directly to a printer. These statements can indicate:
    • The logical page length and width
    • Fonts
    • Page segments
    • Multiple page types or formats
    • Lines within a page
    • Multiple logical pages on a physical page

    This member must be in the library that is named in the cataloged procedure for initializing the PSF or in a library that is specified in the USERLIB parameter.

    Formdef
    Type the name of a member on the z/OS system that contains statements to direct the PSF how to print a report data set on a page-mode printer such as the 3800 Printing Subsystem Model 3. These statements can indicate:
    • Overlay forms to use during printing
    • The location on a page where the overlays are to be placed
    • Suppressions that can be activated for specific page format

    This member must be in the library that is named in the cataloged procedure for initializing the PSF or in a library that is specified in the USERLIB parameter.

    Forms
    Type the name of the form on which the report data set is to be printed or punched. This name can be up to eight characters long and is composed of alphanumeric characters or national characters ($, #, @).
    UCS
    Type the name of the universal character set (UCS) that JES is to use when printing the SYSOUT data set. This value can be up to four characters long.
    FCB
    Specify the Forms Control Block (FCB) name that JES is to use when printing the SYSOUT data set. This name can be up to four characters long
    OPTCD
    The default value is blank. The only other valid value for this field is J.
    PRMODE
    Indicates a printer process mode (Prmode).
    TRC
    Select Yes or No from the list to indicate whether the logical records for the report data set contain table reference character (TRC) codes. A TRC code indicates which font in the Char arg tbl field to use for printing a record. Select either Yes (include TRC codes) or No (do not include TRC codes).
    Copies
    Specify the number of copies to print. You can specify a number from 0 through 255 (on JES2). The default value of 0 indicates that no copies should be physically printed. Corresponds to the JCL COPIES parameter.
    Priority
    Specify a print priority value from 0 (lowest priority) to 255 (highest priority). The higher the priority value, the sooner a report is printed.
    Writer
    Type the name of the external writer that is to process the report data set instead of JES. This name can be up to eight characters in length.
    Duplex
    Select the duplex mode in which to print the report. The list includes the following options:
    • No - Print the report on one side of the paper only (not duplexed).
    • Normal - Print the report on both sides the paper (duplexed) and bind it along the long edge of the paper.
    • Tumble - Print the report on both sides of the paper (duplexed) and bind it along the short edge of the paper.
    Line count
    Type the maximum number of lines that can be printed per page. You can specify a value from 0 through 255. (This field applies to only to JES2 systems.)
    Chars
    Specifies the name of one or more coded fonts for printing SYSOUT on an AFP printer. Corresponds to the CHARS parameter.
    Burst
    Type either YES or NO to indicate whether you want to physically 'burst' reports. This process separates a report into smaller reports based on specific criteria such as branch number.
    Flash
    Type the name of the forms overlay frame to be inserted into the printer before printing the report data set on a 3800 printer. You can specify the name of a specific forms overlay frame. This name can be up to four characters in length and can be composed of alphanumeric characters and national characters ($, #, @). Alternatively, you can specify NONE to suppress flashing for the SYSOUT data set.
    Modify
    Type the name of a copy-modification module that specifies how to print the SYSOUT on a 3800 printing subsystem. Corresponds to the MODIFY parameter.
    Copy grp
    Specify how many copies of each page are to be printed, with a maximum of eight group-values. Each group-value is 1 through 3 decimal values. Each group-value is 1 through 3 decimal numbers, with a valid range from 1 through 255. Corresponds to the COPYG parameter, COPYG=(group-value[,group-value]...). The default for these fields is 0.
    Page Ranges
    Specify the pages, range of pages, or multiple ranges of pages, that are to be printed. This option allows you to specify that only part of the report is to be printed (partial reprint). You can specify individual pages with a space between each page number, (for example 1 3 5 7), or a range of pages using a colon (for example specifying 1:5 prints pages 1 through 5, inclusive). When specifying a range of pages, the first number must be smaller than the second number.
  4. When you are ready to print, click the OK button or press Enter. The report is queued for printing.