KGW configuration parameters
The configuration parameters for the OMEGAMON AI for CICS TG component are grouped logically in the configuration file.
This section explains the parameters found in the OMEGAMON AI for CICS TG area of the PARMGEN configuration profile. The prefix associated with OMEGAMON AI for CICS TG is KGW.
The GBL_DSN_CICS_CTG_DLL runtime environment parameter is required for the OMEGAMON AI for CICS TG product configuration. This parameter is used to specify the data set name of the CICS® Transaction Gateway Dynamic Link Library. This library contains the CTGSTATS program, which is dynamically called during runtime. If multiple versions of OMEGAMON AI for CICS TG are being monitored, then specify the library which corresponds to the highest version being monitored by the agent.
If you specify Y
, for the CONFIGURE_CICS_TG_KGW parameter of OMEGAMON AI for CICS TG, the KGW parameters are
generated and used in the runtime environment configuration. If the value is N
,
then all KGW parameters are ignored.
The following parameters are located in the configuration profile (either your rte_name or $CFG$IBM) file. They are grouped and listed here in the order they might be used to configure the initial values for the various OMEGAMON AI for CICS TG features:
- OMEGAMON for CICS TG agent RKGWXMnn XMIT number
- CICS TG Statistics API and client manager options (client configuration parameters)
- Gateway Daemon statistics collection table
- IBM® Tivoli® Monitoring historical collection for any of the OMEGAMON for CICS TG historical tables
- OMEGAMON for CICS TG agent address space
initialization values (See the Common parameters in the Reference section of OMEGAMON® shared documentation Version 6.3.0 Fix Pack 2 for
a list and description of these shared parameters)
- KGW_AGT*
- KGW_X_AGT*
- These TMS:Engine storage parameters require minimum values
that are greater than these default values:
- KGW_AGT_STORAGE_MINIMUM_EXTEND 256000
- KGW_X_AGT_STORAGE_LIMIT_EXTEND 22
- KGW_X_AGT_STORAGE_RESERVE_PRI 2048
- OMEGAMON for CICS TG agent address space
Tivoli Enterprise Monitoring Server connection
values (See the Common parameters in the Reference section of OMEGAMON shared documentation Version 6.3.0 Fix Pack 2 for
a list and description of these shared parameters)
- KGW_TEMS*
- Indicate whether IBM Tivoli Monitoring historical
data collection will be configured at the Tivoli Enterprise Monitoring Server or the
agent (See the Common parameters in the Reference section
of OMEGAMON shared
documentation Version 6.3.0 Fix Pack 2 for a list and description
of these shared parameters)
- KGW_PD_HISTCOLL_DATA_IN_TEMS_STC
- KGW_PD_HISTCOLL_DATA_IN_AGT_STC
More information about the OMEGAMON AI for CICS TG parameters can be found in the alphabetic list of KGW parameters in this section.