MVS modules

To display modules that have been loaded into the CICS® region by an MVS™ load macro, select the Modules option (E) on the MVS path or enter fast path M.E from any panel.

The MVS Loaded Modules panel is displayed in the following figure:

Figure 1. MVS Loaded Modules in the CICS Address Space Panel (M.E)
 ________________ ZMMODS  VTM     CICSSP31 V530./C SP22 11/23/13 15:51:03 
> PF1 Help     PF3 Back     PF4 Main Menu     PF7 Up    PF8 Down

> A-System Graph   B-System Summary   C-PSW   D-TCBs  E-Modules   F-Subpools
===============================================================================

>                  MVS LOADED MODULES IN THE CICS ADDRESS
SPACE

 PEEK  $CICSTOR ASID=223  >> OB8112: Data Collection Initiated <<
 mods
+      Module    Entry     Length    Users  Attributes
+      #CA-ENF#  00001000  00001000    256  RENT,REUS,AUTH,AC=1
+      DFHSKTSK  000080C0  00000028      1  RENT,REUS,AUTH
+      DFHMNSVC  85797250  00000790      1  RENT,REUS,AUTH
+      ACFF9SUB  00644730  000058D0      3  RENT,REUS,AUTH
+      ACFFEPCS  00643820  000007E0      1  RENT,REUS,AUTH
+      ACF75DCM  0063F5A0  00002A60      1  RENT,REUS,AUTH
+      ACF70CMP  00639600  00005A00      1  RENT,REUS,AUTH
+      ACF61CMD  0062F090  00009F70      2  RENT,REUS,AUTH
+      ACFCMPLR  0062F090  00009F70      0  RENT,REUS,AUTH,ALIAS(ACF61CMD)
+      ACFDCMPL  0062F750  00009F70      0  RENT,REUS,AUTH,ALIAS(ACF61CMD)
+      ACFAEENR  0058F288  00000578      1
+      ACFAEENF  000433D8  00000598      1
+      ACFAEACX  005EA3E0  00009C20      1
+      ACFAEICX  005DE640  0000B9C0      1
+      ACFAEDFH  005D8000  00006000      1
+      ACFAEOM1  005D4D08  000032F8      1
+      OCCCENFD  851D4BB8  00000240      1  RENT,REUS,AUTH
+      OCDBINFD  8577A5A8  000008A0      1  RENT,REUS,AUTH
+      OCDBSP0D  851ED288  000003E0      1  RENT,REUS,AUTH
+      OCDBST0D  857B0EA8  00002240      1  RENT,REUS,AUTH
+      OCEXECFD  005D3298  00000DE0      1  RENT,REUS,AUTH
+      OCGLUEFD  857AE9B8  000016C0      1  RENT,REUS,AUTH
+      OCTRUEFD  00595590  00000A00      1  RENT,REUS,AUTH
+      OCQRYCFD  851D4DF8  000002E0      1  RENT,REUS,AUTH
+      OCXMCR0D  85798748  00001640      1  RENT,REUS,AUTH
+      OCXMST0D  8527B640  00000740      1  RENT,REUS,AUTH
+      OCOMK0FD  851D3D08  00000320      1  RENT,REUS,AUTH
+      OCCOMM00  005D1028  00001040      1  AUTH
+      DFHIRW00  84A666A0  00000228      1  RENT,REUS,AUTH
+      DFHJCOCP  00597278  00000DB0      1  AUTH
+      DFHWTI    8577C628  000029F8      1  RENT,REUS,AUTH
+      DFHXSS    00595F9C  00001148      1  RENT,REUS,AUTH
+      DFHASV    00594690  00000990      2  RENT,REUS,AUTH

This panel includes the name of each module along with its entry point address, length, use count, and load module attributes. The modules displayed may include monitors, vendor packages, DB2®, DLI, and certain nucleus modules. Note that the display does not include CICS programs loaded into DSA.