Completing the upgrade
After you have completed the configuration steps for the appropriate upgrade scenario, there are additional steps you may need to complete.
- OMEGAMON enhanced 3270 user interface
- If you are enabling the enhanced 3270 user interface for the first
time, the following steps must be completed:
- Define the new started task user IDs to your STC table. The default name is IBMTOM.
- Define the new VTAM APPLID for the enhanced user interface. The default name is CTDOBAP.
- APF-authorize &rte_hilev.&rte_name.RKANMODP library, as this load library is included in the STEPLIB DDNAME of all started tasks.
- Customize the KOB* parameters as desired.
- Add the new address space to the system PROCLIB and add its VTAM
major node to the system VTAMLST. If you are using a global VTAM major
node, refresh the global VTAM major node with the user interface's
VTAM LOGON APPLID.
In PARMGEN, the KCIJPSYS job is available to perform these steps. In ICAT, copying the STC from RKANSAMU to system procedure library and system VTAMLST library is a post-configuration step.
In a PARMGEN upgrade, steps 1-3 are done automatically (and step 5 if the KCIJPSYS job is run). In a Configuration Tool upgrade, these steps must be performed manually.
After you have completed configuration, run the appropriate load job and recycle started tasks in the upgraded runtime environment.