KS3T622E STORAGE TOOLKIT RUNTIME PARAMETER MEMBER KS3ACTIN OPEN ERROR RETURN CODE [return_code]
Explanation
This message indicates that an internal error has occurred. The [return_code] has these possible values and meanings: 4=Invalid handle, 5=Unsuccessful - open failed, 8=Dynamic allocation failed, 9=DSNAME greater than 44 characters, 10=DDNAME greater than 8 characters, >256=An abend occurred. The value is (abendcode * 256). Divide the value by 256. If the result is less than 4096, this is a system abend. If the result is greater than 4096, subtract 4096 to determine the user abend code.
System action
OMEGAMON for Storage continues, but the operation triggering the error does not complete.
User response
Contact IBM® Software Support. This problem information is stored in the ITMS:Engine log, RKLVLOG.