This message indicates that an internal error has occurred. Collection for dataset groups was specified or defaulted as RMF, however module [module_name] has not been able to synchronize recording with the RMF interval. RC=[n] indicates the reason that the recording interval defaulted to 15 minutes. Return codes are:
0 - OK
4 - Interval=0 from API
8 - NO STGST address
12 - NO RMF routine address
16 - Parm area address in R1=0 on entry
20 - RMF Routine address is dummy
24 - Interval = 0 from control blocks
28 - Interval less than 1 minute
32 - Load failed for KDFDRMFI
36 - KDFDRMFI entry point not found
System action
A 15 minute collection interval is used; processing continues.
User response
The destination is the Tivoli® Enterprise Monitoring Server Engine log file, RKLVLOG. If this message persists and RMF monitor 1 is active contact IBM® Software Support with the return code information.