KS3G041W [module_name] - RMF SYCHRONIZATION FAILED - RC=[n] - COLLECTION INTERVAL DEFAULTING TO 15 MINUTES

Explanation

This message indicates that an internal error has occurred. Collection for dataset groups was specified or defaulted as RMF, however module [module_name] has not been able to synchronize recording with the RMF interval. RC=[n] indicates the reason that the recording interval defaulted to 15 minutes. Return codes are:
  • 0 - OK
  • 4 - Interval=0 from API
  • 8 - NO STGST address
  • 12 - NO RMF routine address
  • 16 - Parm area address in R1=0 on entry
  • 20 - RMF Routine address is dummy
  • 24 - Interval = 0 from control blocks
  • 28 - Interval less than 1 minute
  • 32 - Load failed for KDFDRMFI
  • 36 - KDFDRMFI entry point not found

System action

A 15 minute collection interval is used; processing continues.

User response

The destination is the Tivoli® Enterprise Monitoring Server Engine log file, RKLVLOG. If this message persists and RMF monitor 1 is active contact IBM® Software Support with the return code information.