KDFD002W KDFDEVIN: SMFDINTV VALUE=OFF; SMF DEVICE RECORDING DISABLED

Explanation

The KDFDEVIN member of a dataset pointed to by the RKANPAR DD statement for the Tivoli® Enterprise Monitoring Server address space contains the parameter SMFDINTV(OFF).

System action

SMF recording is disabled within the Tivoli Enterprise Monitoring Server.

User response

None. This message is informational. To enable SMF recording within the Tivoli Enterprise Monitoring Server, specify a valid recording interval for the SMFDINTV parameter and a valid SMF user record number for the SMFRECN parameter. The SMFDINTV parameter accepts the following values:
RMFSYNC
Synchronizes with the RMF interval.
SMFSYNC
Synchronizes with the SMF interval.
1-1439
Specifies the recording interval in minutes.

Specify a user record number from 128 to 255 for the SMFRECN parameter. Restart the Tivoli Enterprise Monitoring Server address space. The destination is the Tivoli Enterprise Monitoring Server Engine log file, RKLVLOG.