KDFAP0020S SERVICE PROBES NOT INITIALIZED

Explanation

An attempt was made to use the OMEGAMON® for Storage action services before they were made available.

System action

OMEGAMON for Storage continues to run, however the action service probes cannot be executed. The destination is the RKLVLOG from the Tivoli® Enterprise Monitoring Server address space.

User response

In order to run the action service probes, the Tivoli Enterprise Monitoring Server component must be fully initialized. If it is not, initialize Tivoli Enterprise Monitoring Server and retry the probes. If the Tivoli Enterprise Monitoring Server component was initialized and already issued the message KLVIN408 CANDLE ENGINE VERSION 170 READY , then check the Tivoli Enterprise Monitoring Server RKLVLOG for these informational messages:
KDFAP0000I SERVICE PROBES INITIALIZATION HAS		
COMMENCED KDFAP0001I SERVICE PROBES ANCHOR BLOCK 
HAS BEEN CREATED 
If these messages are found, the service probes should be initialized. Contact IBM® Software Support for further information. If these messages are not found, then the action services probes have not been initialized. To investigate further:
  • Search the RKLVLOG of Tivoli Enterprise Monitoring Server for any related error messages.
  • Ensure that the RKANPAR datasets for Tivoli Enterprise Monitoring Server are correct.
  • Ensure that the RKANPAR dataset members have not been inadvertently modified. Correct any errors and restart Tivoli Enterprise Monitoring Server.
If further assistance is necessary, contact IBM Software Support.