The final step in setting up the runtime environment (RTE) using the configuration
software is submitting the batch jobs that were created in the preceding step. These jobs allocate
the necessary data sets.
Procedure
From the Workflow - Primary Option Menu, select Submit
batch jobs to complete PARMGEN setup.
KCIPQPGB PARAMETER GENERATOR (PARMGEN) WORKFLOW - PRIMARY OPTION MENU --------
Option ===>
Quick Configuration Mode
GBL_USER_JCL: TDITN.IDTST.PARMGEN.JCL
RTE_PLIB_HILEV: TDITN.IDTST
RTE_NAME: SYSA
Notes: Perform steps 1 through 5 in sequence, repeating steps as necessary.
If reconfiguring this RTE, see Maintenance Scenarios F1=Help topic.
Enter n (1-5) to perform tasks.
Enter ns (1s-5s) for detailed job/task status.
Description Job/Label Status Date
-------------------------------------------- --------- --------- ----------
1. Set up/Refresh PARMGEN work environment. KCIJPCFG
2. Customize PARMGEN configuration profiles. SYSA
3. Create this RTE's runtime members and jobs. $PARSE Enter 3 for details.
4. Submit batch jobs to complete PARMGEN setup. SUBMIT Enter 4 for details.
5. Perform post configuration steps. POSTCFG
R Create next RTE - Reset fields. New RTE
Press F1=Help for more information. Type U or UTIL to access utility menu.
The Submit Batch Jobs To Complete PARMGEN Setup panel
(KCIP@SUB) is displayed.
KCIP@SUB -------- SUBMIT BATCH JOBS TO COMPLETE PARMGEN SETUP -----------------
Option ===>
Select option 1 to SUBMIT the composite jobs in WKANSAMU for SYSA RTE.
Tip: Review the SUBMIT commands in the KCIJPSUB composite job.
Alternatively, select other options (2-12) to submit each job individually.
Enter ns (1s-12s) for detailed job/task status.
Description REQ Job Name Status Date
--------------------------------------- ----- -------- --------- ----------
More: +
1. Composite SUBMIT job (See JCL comments) KCIJPSUB
** or **
2. Allocate runtime RO and RW datasets (Yes) KCIJPALO
3. Copy SMP/E mbrs from TK*->RK* RO libs (Yes) KCIJPLOD
4. Run product security steps (Yes) KCIJPSEC
5. Update variable-named runtime mbrs (No ) KCIJPUPV
6. (Re)Create USS runtime mbrs in RKANDATV (Yes) KCIJPUSP
7. Create USS dirs./ (Re)Copy USS files (Yes) KCIJPUSS
8. Copy runtime mbrs to SYS1-type libs (Caution) KCIJPSYS
9. Run post-SMP/E RKANMODU ASM/LINK steps (Yes) KCIJPLNK
10. Verify the configuration jobs (Tip) KCIJPIVP
11. Back-up RK* product execution user libs (Tip) KCIJPCPR
12. Copy runtime mbrs from WK*->RK* RW libs (Yes) Enter 12 for details.
Press F1=Help for more information. Type UTIL to access utility menu.
The jobs that you need to submit to set up this RTE are indicated by a Yes in the REQ
column.
Submit the required jobs by using the composite SUBMIT job.
Before you submit the Composite SUBMIT job, review and edit it as
necessary. For example, OMEGAMON AI for JVM uses z/OS®
UNIX® System Services and the user that submits the job must
have SUPERUSER and READ access to BPX.FILEATTR.* profiles (BPX.FILEATTR.APF, BPX.FILEATTR.PROGCTL)
in the FACILITY class. Because the user who has been configuring the RTE may not have the correct
authorization in place, specific jobs can be excluded from the composite job and submitted
separately by a user who does have the correct authorization.
Note: After you submit the required
jobs or the composite job, you still need to copy the product started tasks and the VTAM major node
members to the system libraries. You can copy the product started tasks and VTAM major node members
by running either your own jobs or the PARMGEN KCIJPSYS job. You can review the KCIJPSYS job
overview to get a list of items that you must copy.
If the jobs complete with any errors, review the $IVPRPT verification report in the WCONFIG
library. Correct any errors and rerun any jobs that did not complete successfully. Rerun the
KCIJPIVP verification job until all errors have been eliminated.
What to do next
Note: Make sure the following started task run in a proper service class in Work Load Manager:
The started task of the OMEGAMON AI for JVM agent and collector: IBMJJ and IBMJT.
Make sure the service class of the started tasks are equal to or higher than that of the object they
are monitoring.
Then complete any configuration required outside of the configuration software.