OB1116 REQUEST NOT SUPPORTED
Explanation
The request is not supported by the target collector.
System action
The IPRO command processor suppresses the display.
User response
Correct the parameters and retry the request.
The request is not supported by the target collector.
The IPRO command processor suppresses the display.
Correct the parameters and retry the request.
The IPRO collector’s data is currently statistically invalid. Sufficient data has not yet accumulated for a meaningful display.
The IPRO command processor suppresses the display until enough samples have accumulated.
Wait for sufficient time to gather data. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The requested data is not being collected at this time.
The IPRO command processor suppresses the display.
Stop and restart the collector requesting the required data, or correct the collector start-up parameters and retry the request.
The IPRO display parameters are not valid, so the processor suppresses the display.
The extractor was unable to process the parameters successfully.
Correct the parameters and retry.
An error occurred in the IPRO data display extractor. No presentation is made during this cycle.
The IPRO command processor suppresses the display.
Contact IBM Software Support.
OMEGAMON could not find the Impact Analysis processor module to load.
The IPRO command processor suppresses the display.
If this module should be available, contact IBM Software Support.
No extractor identification was given to the IPRO command processor. Either this is the first time the command was used, or it was cleared by the first extractor and there are no new operands.
The IPRO command processor suppresses the display.
Supply a proper extractor ID.
The IPRO display processor for xxxx could not be located in this set of OMEGAMON modules.
The IPRO command processor suppresses the display.
Contact IBM Software Support.
The IPRO display processor returned the code cc which is unknown to the IPRO command.
The IPRO command processor suppresses the display.
Contact IBM Software Support.
The first 4 characters (cccc) of the operand are invalid.
The IPRO command processor suppresses the display.
Specify a valid IPRO collector and retry.
The IPRO command is not supported at this product level. IPRO requires DEXAN.
The IPRO command processor suppresses the display.
Contact IBM Software Support.
ISPF has returned a severe error condition code to the OMEGAMON ISPF driver.
The ISPF session terminates.
Look for other messages and take appropriate action.
The TSO service task has returned the error code indicated.
The ISPF session terminates.
Examine the error code and take appropriate action. Refer to the IBM® manual, TSO Extensions User’s Guide.
ISPF issued a non-zero return code in response to /ATTACH.
The ISPF session terminates.
Examine the return code and take appropriate action.
The monitor task (OMEGAMON) terminated with the indicated return code.
The task terminates.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The monitor task (OMEGAMON) terminated with the indicated abend code.
The task terminates.
Contact IBM Software Support.
The PARM string entered was too long, causing internal buffer overflow.
The task terminates.
Shorten the PARM string and retry the command.
The ISPF driver module was unable to load ISPLINK, the ISPF interface.
The task terminates.
Make sure a copy is available to the ISPF driver.
The SPF driver module could not find the OMSPF01 panel.
The task terminates.
Be sure the panel is in the correct ISPF library and retry.
The OMSPFD variable was not in the panel.
The task terminates.
Make sure that the correct panel is installed and that user changes have not caused this field to be omitted.
ISPF indicated a short-on-storage condition.
The task terminates.
Increase the TSO address space region and retry.
Internal data truncation occurred within a panel variable.
The task terminates.
Make sure that the variable lengths shown in the panel have not been changed.
A variable that the ISPF driver requires could not be found in the ISPF subpools.
The task terminates.
This is an internal error. Contact IBM Software Support.
The screen parameters are invalid for ISPF mode. COLS and ROWS must match the TSO specification for the device.
The task terminates.
Correct the screen specification parameters (COLS and ROWS) and restart.
ISPLINK returned a code 20 or above to the calling task.
The task terminates.
Contact IBM Software Support.
The request for storage for module cccccccc failed.
The TSO or ISPF mode task terminates.
Increase the region size for the TSO address space.
A non-zero return code from ATTACH of module cccccccc was received.
The TSO or ISPF mode task terminates.
Examine the error code and call your systems support. If the problem persists, contact IBM Software Support.
The module abended with the indicated return code.
The application using the module is terminated.
Examine the abend code and call your systems support. If the problem persists, contact IBM Software Support.
OMEGAMON could not set full-screen mode on as requested for TSO mode.
The task terminates.
Contact IBM Software Support.
OMEGAMON could not set display manager off as requested for TSO mode.
The task terminates.
Contact IBM Software Support.
OMEGAMON could not set full-screen mode off as requested for TSO mode.
The task terminates.
Contact IBM Software Support.
OMEGAMON could not set display manager on as requested for TSO mode.
The task terminates.
Contact IBM Software Support.
The task completed its processing with a normal termination.
The TSO or ISPF mode task terminates.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The free storage request has failed in module cccccccc.
The task terminates.
Examine the error code in the SYSLOG. If the problem persists, contact IBM Software Support.
The load request for module cccccccc has failed.
The task terminates.
Examine the error code in the SYSLOG. Ensure that load module cccccccc is in the proper load library. If the problem persists, contact IBM Software Support.
The delete request for module cccccccc has failed.
The task terminates.
Contact IBM Software Support.
The request to get terminal attributes has failed.
The task terminates.
Contact IBM Software Support.
The user ID field in the logon panel is missing.
OMEGAMON redisplays the logon panel.
Enter the required user ID.
The password field in the logon panel is missing.
OMEGAMON redisplays the logon panel.
Enter your password.
The system asks the user to re-enter the new password.
The system waits for the user to re-enter the new password to verify that the new password is correct.
Enter the new password in the new password field.
When the password was entered a second time for verification, it did not match the new password.
The system waits for the user to attempt another logon.
Enter the correct password.
The argument field contains invalid data for the command that appears above this message on the screen.
OMEGAMON does not process the command.
Enter appropriate data in the command argument field.
OMEGAMON does not have sufficient memory to build the screen member name lists from the various sources (main storage, KOBCICSPROC, and RKOMPCSV) that the SCRN command displays.
OMEGAMON does not process the command.
Provide additional storage resources for the executing OMEGAMON.
There were no members in the indicated KOBCICSPROC data set for the SCRN command to display.
The SCRN command displays member names in the other KOBCICSPROC data sets.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
OMEGAMON found no screen names within the from/through range specified by the SCRN command.
None.
Enter a different from/through selection range.
There are too many screen space members for the LSCR command to load into main storage. The maximum number is 62.
OMEGAMON does not load the screen spaces into main storage.
Reduce the number of members to load.
The LSCR command detected a screen member name that is too long or that contains invalid characters.
OMEGAMON does not load the screen into main storage.
Correct the screen member name on the LSCR command.
The user specified screen space cccccccc with an LSCR command; OMEGAMON did not find it in the KOBCICSPROC library.
OMEGAMON ignores specification of screen space cccccccc and loads any other specified screen spaces.
Make sure that the specified screen space exists in KOBCICSPROC or RKOMPCSV library. Check KOBCICSPROC concatenation.
The LSCR command successfully loaded nnn screen spaces to main storage.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The LSCR command attempted to load screen spaces to main storage, but there were no member names specified.
The command terminates.
Enter member names following the LSCR command.
The user specified screen space cccccccc with a DELTB command, and OMEGAMON successfully deleted it from main storage (in-storage) and RKOMPCSV.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The user specified screen space cccccccc with a DELTI or DELTB command; OMEGAMON did not find it in main storage (in-storage).
None.
Verify that the screen space name is correct.
OMEGAMON successfully deleted screen space cccccccc from main storage (in-storage) as a result of DELTB or DELTI command.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
OMEGAMON successfully deleted screen space cccccccc from RKOMPCSV as a result of DELTB or DELTD command.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The user specified screen space cccccccc with a DELTB or DELTD command, and OMEGAMON did not find it in RKOMPCSV.
None.
Verify that the screen space name is correct.
The user specified screen space oldname with a RENMB command, and OMEGAMON successfully renamed it to newname in main storage (in-storage) and in RKOMPCSV.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The user specified screen space cccccccc with a RENMI or RENMB command; OMEGAMON did not find it in main storage (in-storage).
None.
Verify that the screen space name is correct.
OMEGAMON successfully renamed screen space oldname to newname in main storage (in-storage) as a result of RENMI or RENMB command.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
OMEGAMON successfully renamed screen space oldname to newname in RKOMPCSV as a result of a RENMD or RENMB command.
The command executes.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
The user specified screen space cccccccc on a RENMD or RENMB command, and OMEGAMON did not find it in main storage (in-storage).
None.
Verify that the screen space name is correct.
The PDS directory for file cccccccc is full and cannot contain additional screen space names.
OMEGAMON does not rename the screen space in RKOMPCSV.
Compress the PDS library or provide additional directory space.
The user issued a RENMI or RENMB command with a screen space name cccccccc that already exists in main storage (in-storage) and cannot be renamed.
OMEGAMON does not change the original screen space name.
Correct the new screen space name and retry the command.
The user issued a RENMD or RENMB command with a screen space name cccccccc that already exists in RKOMPCSV and cannot be renamed.
OMEGAMON does not change the original screen space name.
Correct the new screen space name and retry the command.
The data-only space cccccccc specified in the command cannot be found. cccccccc is the name of the data-only space or the first 1–7 characters of the data-only space name. If cccccccc is displayed in the message as less than 8 characters, it means that there were no data-only spaces found beginning with the characters cccccccc.
The command is terminated.
Correct the data-only space name and reissue the command. The PEEK command may be used to find the names of data-only spaces owned by a job.
Job aaaaaaaa is not the owner of data-only space cccccccc. aaaaaaaa is the jobname given in the command or the name of the job identified by the ASID.
The command terminates.
Correct the data-only space name, the jobname, or ASID and reissue the command. The PEEK command may be used to find the names of data-only spaces owned by a job’s TCBs. The OSPC command may be used to find the jobname and ASID of the owning TCB of a data-only space.
The TCB owning data-only space aaaaaaaa of type cccccccc has deleted the space or has itself been terminated. The space no longer exists.
The command is terminated.
None.
Due to an internal OMEGAMON error, OMEGAMON is unable to perform data-only space processing.
The command terminates.
Contact IBM Software Support with the return code.
A data-only space name of greater than 8 characters was entered as input.
The command terminates.
Correct the name of the data-only space. The OSPC command may be issued to obtain the name of all data-only spaces in the system.
A data-only space command (e.g., SLST, SZAP) was issued without the name of a data-only space as input.
The command terminates.
Correct the command input by supplying a data-only space name as the second parameter. The OSPC command may be issued to obtain the name of all data-only spaces in the system.
An attempt to obtain addressability to a data space failed with return code nn.
The command terminates.
Ensure that the data space input to the affected command has not been deleted. If the data space still exists, contact IBM Software Support.
An attempt to access a Hiperspace™ failed with return code xx.
The command terminates.
Contact IBM Software Support.
An attempt was made to access a non-shareable data-only space aaaaaaaa of type cccccccc without authorization.
The command terminates.
Authorization may be obtained to non-shareable data-only spaces by issuing the command .DSAON.
An attempt was made to access data space aaaaaaaa, but OMEGAMON was not able to determine the SCOPE of the data space.
The command terminates.
Contact IBM Software Support.
OMEGAMON attempted to access module OBRMFSnn but failed.
The command terminates.
Check to make sure that the OBRMFSnn modules were copied from the OMEGAMON distribution tape. If the modules are in the OMEGAMON load library, contact IBM Software Support.
An attempt was made to set the RMF level to a level that OMEGAMON did not recognize.
The command terminates.
Check to make sure that the correct RMF level is entered on the input screen. If it is entered correctly but OMEGAMON does not recognize it, contact IBM Software Support. You may need to receive support for a new level of RMF.
The operand on the RMFS command must have the format nnn or n.n.n.
The command terminates.
Correct the input to the RMFS command and press ENTER.
OMEGAMON determined the level of RMF dynamically. RMFS cannot be used to override the RMF level in this situation.
The command terminates.
None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.
An attempt was made to change to a new level of RMF, however, the required load module was not available.
The command terminates. The RMF level stays unchanged.
Make sure that the load module is copied from the installation tape. If the module is not on the tape, contact IBM Software Support.
A call to the Candle Subsystem has resulted in a non-zero return code.
A common cause of this return code is a version or maintenance level mismatch between the running Candle subsystem and the product issuing the message. If you have multiple SMP/E environments make sure that all have the same Candle subsystem FMID and maintenance installed.
The interface to the Candle Subsystem returns the address of the static device table that might be obsolete. You may also need a later version of the Candle Subsystem.
Contact IBM Software Support.
There is not enough memory available for the user profile tables.
The command terminates.
Increase the region size and retry.
OMEGAMON attempted to locate the corresponding base module required for the current operating system level. The required module could not be found.
OMEGAMON terminates.
Make sure that OMEGAMON is executed at the operating system level for which your installation is licensed. Contact IBM Corporation for licensing and sales information.
OMEGAMON has determined that the current operating system level is not supported. Only MVS/SP™ 1, 2, and 3 are supported; earlier versions are not supported. (SP™ 1 support is further limited to SP 1.3 and above.)
OMEGAMON terminates.
Run OMEGAMON only on those systems with supported operating system levels.
The OVUSERcc DATA file specified by USER xx in the startup parms or the .USR command was not found.
OMEGAMON® uses all default values for execution parameters. The default OVUSER DATA file is 99.
Continue with OMEGAMON initialization or restart OMEGAMON specifying the correct USER startup parameter value, or reissue the .USR command specifying the correct parameter.
The indicated parameter must be specified as either ON or OFF.
OMEGAMON uses the default value.
Correct the parameter value to specify ON or OFF at next execution.
The indicated word is not a valid OMEGAMON startup parameter.
OMEGAMON ignores the entire parameter group (including any possible subordinate keywords).
Check for spelling problems. Check to make sure that a previous parameter was not continued incorrectly.
The format of the indicated input stream is invalid.
OMEGAMON ignores either all or part of the current parameter group.
Correct the formatting error. Ensure that all required delimiters (commas, parentheses, and so on) are entered correctly.
An invalid character was found in the input stream.
The character is assumed to be a delimiter.
Enter a valid character if a delimiter was not intended.
The indicated word is not a valid keyword for the current parameter group being processed.
OMEGAMON ignores the keyword.
Check for possible spelling or continuation errors.
The value specified for the indicated parameter keyword is invalid.
OMEGAMON ignores the keyword.
Specify the keyword value as required.
EBCDIC characters were specified for a keyword requiring hexadecimal data.
OMEGAMON ignores the keyword.
Correct the keyword value.
EBCDIC characters were specified for a keyword requiring numeric data.
OMEGAMON ignores the keyword.
Correct the keyword value.
The value specified for the indicated keyword is either too short (character) or too small (integer or hex).
OMEGAMON ignores the keyword.
Check the minimum that can be specified for the keyword and correct the keyword value.
The value specified for the indicated keyword is either too long (character) or too large (integer or hex).
OMEGAMON ignores the keyword.
Check the maximum that can be specified for the keyword and correct the keyword value.
A duplicate keyword has been found in the input stream.
OMEGAMON ignores the duplicate parameter.
Remove or correct the duplicate keyword.
The internal buffers required to hold the data specified by the OVUSER MISSVM parameter have overflowed.
The MISSVM keyword specifications that will fit in storage will be accepted with the remainder ignored.
Increase the virtual storage size of the OMEGAMON for VM virtual machine or specify few MISSVM keyword values.
The internal buffers required to hold the data specified by the OVUSER MISSDA parameter have overflowed.
The MISSDA keyword specifications that will fit in storage will be accepted with the remainder ignored.
Increase the virtual storage size of the OMEGAMON for VM virtual machine or specify few MISSDA keyword values.
For the PGNAMES parameter a USERID= or ACCOUNT= keyword was expected and not found.
OMEGAMON ignores the entire PGNAMES parameter group.
Check for a spelling error to ensure that either a USERID= or an ACCOUNT= keyword is specified.
While processing a continuation, the end of the OVUSERcc DATA file was reached.
OVUSERcc parameter processing terminates.
Check to see if the OVUSER DATA file is complete. If not, enter the missing parameter keyword(s).
The NAME keyword was not specified on the PGNAME statement.
OMEGAMON ignores the entry.
The PGNAME statement requires a name for each group being defined. Specify a name.
Either an unexpected parenthesis was detected or an expected parenthesis was not detected.
OMEGAMON ignores either the current keyword or the remaining parameter keywords.
Add or remove parentheses as required.
For the PGNAMES parameter group more than 64 performance groups were specified.
OMEGAMON ignores the remaining performance groups.
Remove less important performance groups so that the maximum will not be exceeded.
A keyword for the DEFVMTG, DASDTG, or RSCSTG parameter was entered that is not a valid exception override name.
OMEGAMON ignores the keyword.
Check for a possible spelling error. For DEFVMTG, ensure that the exception name entered is a valid VM exception and not a SYSTEM exception. For DASDTG, ensure that the exception name entered is one of the DASD exceptions. For RSCSTG, ensure that the exception name entered is RSCA or RSCQ.
The indicated parameter must be specified as either ON or OFF.
The keyword value defaults to ON.
Correct the parameter value to specify ON or OFF.
A parenthesis was expected at or near the column indicated by an asterisk.
OMEGAMON ignores the current keyword.
Check the format for the keyword and make the appropriate corrections.
The indicated parameter must be specified as either ON or AUTO.
Missing VM analysis for this VM user ID defaults to AUTO.
Correct the parameter value to specify ON or AUTO.