OB0953 DDNAME MISSING
Explanation
This message may be issued in either of two situations:
- When the /ATTACH command is issued and OMEGAMON did not find the correct DD statement for the cross system data set.
- When attempting to start a collector and OMEGAMON did not find the correct DD statement for the cross system data set.
System action
OMEGAMON cancels the request.
User response
To correct the error, check the following:
- A collector system ID for the session that matches the name specified on the SYS= start-up parameter.
- A missing or incorrect DD statement in the director start-up JCL or EXEC file to point to the cross system data set.
- A missing or incorrect DD statement in the collector start-up JCL or EXEC file to point to the cross system data set.
When you have corrected the error, restart the OMEGAMON director.