OB0801 INFORMATION UNAVAILABLE—INTERNAL ERROR

Explanation

In response to the .VTM command, OMEGAMON attempted to display multi-session status information. However, OMEGAMON detected one or more problems in the internal subtask configuration for OBVTAM. This problem may be caused by transitory changes in OBVTAM subtask structures, which could result in a program check.

System action

The command terminates.

User response

Reissue the command. If this message persists, contact IBM Software Support.

OB0802 NO DATA ONLY SPACES ARE OWNED BY THIS ADDRESS SPACE

Explanation

No tasks within the address space specified by the PEEK major command own any data-only spaces.

System action

The command terminates.

User response

None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.

OB0803 ERROR DETECTED IN INTERNAL SCAN ROUTINE

Explanation

An internal subroutine detected an error while collecting information on data-only spaces for the specified address space.

System action

The command terminates.

User response

Try the command again. If this message persists, contact IBM Software Support.

OB0900 COMMAND cccc IS NOT A VALID COMMAND

Explanation

The command cccc is not a minor of the current major command or is not itself a major or immediate command.

System action

OMEGAMON bypasses this line.

User response

Correct the command and retry.

OB0901 COMMAND SUPERSEDED BY cccc

Explanation

OMEGAMON no longer supports the specified command. Command cccc now performs a similar function.

System action

OMEGAMON selects the new version of the command.

User response

None. In the future, use command cccc.

OB0902 COMMAND INVALID UNDER nnn

Explanation

This command is not valid with the MVS version you are running (nnn).

System action

OMEGAMON selects the next command.

User response

Use this command with the correct version of MVS.

OB0903 INVALID INFO-LINE COMMAND

Explanation

The INFO-line command entered does not exist.

System action

The command is not executed.

User response

Correct the command and retry.

OB0906 COMMAND DISABLED

Explanation

The specified command was disabled by user security processing.

System action

OMEGAMON bypasses this line.

User response

Issue another command.

OB0910 PROGRAM CHECK - RECOVERY SUCCESSFUL - xxxxxxxx

Explanation

An OMEGAMON command terminated abnormally due to a program check at location xxxxxxxx.

System action

OMEGAMON aborts the command.

User response

Retry the command. If the problem persists, follow the instructions given in the Preface, then contact IBM Software Support.

OB0915 CROSS MEMORY ERROR, ADDRESS SPACE SWAPPED OUT

Explanation

Cross memory operations were attempted to an address space that was swapped out.

System action

Program recovery is successful, although the operation is suppressed.

User response

None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.

OB0916 PATTERN MUST BE SET BY .SPT COMMAND

Explanation

A pattern-controlled operation was requested, but the pattern was not defined.

System action

Operation is ignored.

User response

Set a proper pattern using the .SPT command.

OB0917 PATTERN ARGUMENT MUST BE NUMERIC

Explanation

The command requires a pattern that only has numeric values.

System action

Pattern operation is ignored.

User response

Correct the command and retry.

OB0918 NO PATTERN EXISTS

Explanation

No pattern exists for the requested pattern number.

System action

Pattern operation is ignored.

User response

Correct the command or assign a pattern.

OB0919 PATTERN NUMBER MUST BE 0 THROUGH 9

Explanation

Invalid pattern number.

System action

Pattern operation is ignored.

User response

Correct the command and retry.

OB0920 COMMAND LOOP—RECOVERY SUCCESSFUL

Explanation

OMEGAMON built-in loop detection encountered a possible loop in an OMEGAMON command processor.

System action

OMEGAMON terminates the command.

User response

Use the .SET command to increase the LOOPTIME and/or LOOPCOUNT values. If the problem persists after setting these values to the maximum, follow the instructions given in the Preface and contact IBM Software Support.

OB0921 SECURITY CHECK FAILED (INTERNAL)

Explanation

A password was not supplied for the security level associated with this command.

System action

OMEGAMON suppresses the command.

User response

Supply a valid password, or see your security administrator.

OB0922 SECURITY CHECK FAILED (EXTERNAL)

Explanation

The OMEGAMON external security interface determined that the command is not authorized for execution.

System action

OMEGAMON suppresses the command.

User response

See your security administrator.

OB0924 cccc COMMAND NOT VALID WITH cc ARGUMENT

Explanation

This command does not support a .D or a .R argument.

System action

The command is not executed.

User response

Correct the command syntax and retry.

OB0925 LOOP IN OMEGAMON BASE

Explanation

OMEGAMON’s built-in loop detection encountered a possible loop in an OMEGAMON service module.

System action

OMEGAMON terminates with a user ABEND 0925.

User response

Use the .SET command to increase the LOOPTIME and/or LOOPCOUNT values. If the problem persists after setting these values to the maximum, follow the instructions given in the Preface and contact IBM Software Support.

OB0926 LOOP IN OMEGAMON BASE TERMINATION

Explanation

A loop was detected while termination operations were under way.

System action

Termination operations are suspended and OMEGAMON abends.

User response

If the problem persists, contact IBM Software Support.

OB0930 UNEXPECTED PROGRAM CHECK - xxxxxxxx

Explanation

OMEGAMON abend protection (ESTAE) processing detected a program check error in a module at location xxxxxxxx.

System action

OMEGAMON terminates the command.

User response

Follow the instructions given in the Preface, then contact IBM Software Support.

OB0931 CP LOCATE OR CANDLE DIAGNOSE REQUIRED

Explanation

The command cannot be executed without having either the authority to issue the CP LOCATE, or the IBM® Tivoli® Candle User Diagnose installed.

System action

OMEGAMON® terminates the command.

User response

Get the privilege class needed to execute the CP LOCATE command or install the IBM Tivoli CandleUser Diagnose as documented in the OMEGAMON and EPILOG for VM Installation and Customization Guide and regenerate the VM operating system.

OB0932 CANDLE DIAGNOSE OR CP LOCK COMMAND REQUIRED

Explanation

The command cannot be executed without having either the IBM Tivoli Candle User Diagnose installed or authority to issue the CP LOCK command.

System action

OMEGAMON terminates the command.

User response

Install the IBM Tivoli Candle User Diagnose as documented in the OMEGAMON and EPILOG for VM Installation and Customization Guide and regenerate the VM operating system, or get the privilege class needed to execute the CP LOCK command.

OB0933 OMEGAMON resource cleanup initiated for abend ccccc RC=xxxxxxxx

Explanation

An abend occurred for an OMEGAMON session, and the non-private area resources will be removed. ccccc is the abend code and xxxxxxxx is the return code associated with the failure. This message is always followed by OB0935.

System action

Termination continues.

User response

None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.

OB0934 LOAD FAILED FOR USER SECURITY EXIT - cccccccc

Explanation

At initialization, this message appears if OMEGAMON was unable to load the designated user security exit.

System action

All EXTERNAL=YES commands with associated security levels of 0 are disabled.

User response

Ensure that the user security exit is specified in the MODULE= keyword of the security update program.

OB0935 OMEGAMON RESOURCE CLEANUP COMPLETE

Explanation

Abend processing removed non-private area resources in preparation for abnormal termination.

System action

Termination continues.

User response

None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.

OB0936 WARNING—RUNNING KOBASnnn ON MVS/SPmmm. USE KOBASbbb.

Explanation

The MVS version level of OMEGAMON you are attempting to initialize (nnn) does not match the MVS version under which you are running (mmm). Because we do not distinguish among all possible MVS variations, mmm can be 13x, 2xx, or 3xx. The variable bbb is the correct level.

System action

The system prompts you on whether you want to continue initialization. If you do continue to run an OMEGAMON version that does not match the MVS version level, the integrity of some OMEGAMON data may be compromised.

User response

Determine whether your site is licensed for the version of OMEGAMON that matches your MVS level. If so, check the version level specified in the start-up parameters and change nnn to bbb. If not, contact IBM Software Support.

OB0937 WARNING—RUNNING MVS/SPnnn MODULE pppppppp ON MVS/SPmmm

Explanation

The variable nnn is the MVS version on which the module (pppppppp) is supported. It does not match the MVS version under which you are running (mmm). Because we do not distinguish among all possible MVS variations, mmm can be one of 13x, 2xx, or 3xx.

System action

The system prompts you on whether you want to continue initialization. If you do continue and run an OMEGAMON version that does not match the MVS version level, the integrity of some OMEGAMON data may be compromised.

User response

Determine whether your site is licensed for the version of OMEGAMON that matches your MVS level. If so, check the version level specified in the start-up parameters and change nnn to bbb. If not, contact IBM Software Support.

OB0938 WARNING—OMEGAMON UNSUPPORTED ON MVS PRE-SP1.3.

Explanation

OMEGAMON no longer supports versions of MVS prior to SP1.3.

System action

The system prompts you on whether you want to continue initialization. If you continue to run an OMEGAMON version that does not match the MVS version level, the integrity of some OMEGAMON data may be compromised.

User response

Upgrade your MVS version.

OB0939 STORAGE UNAVAILABLE FOR COWA

Explanation

A collector is starting and needs memory for the work area to communicate with the director. The request for memory has failed.

System action

The collector terminates.

User response

Increase region size and try again.

OB0940 NO RESPONSE FROM DIRECTOR FOR 5 MINUTES

Explanation

During the last 5 minutes, an OMEGAMON collector session did not detect a response from its associated director session.

System action

OMEGAMON terminates the collector.

User response

Determine why the director failed and restart the session.

OB0941 COLLECTOR CONNECTION FAILED: NO SEGMENTS AVAILABLE

Explanation

The user tried to establish more than the maximum number (7) of cross memory collector sessions with a single OMEGAMON director.

System action

OMEGAMON cancels the request.

User response

If you need to display more than 7 cross memory collectors on this system, start another OMEGAMON director.

OB0942 COLLECTOR AT WRONG VERSION: CONNECTION FAILED

Explanation

A cross memory collector at a different (and incompatible) release level tried to start a cross memory session with an OMEGAMON director.

System action

OMEGAMON cancels the request.

User response

Bring up the director and cross memory collector using the same (or a compatible) version of OMEGAMON.

OB0943 NO RESPONSE FROM COLLECTOR FOR 5 MINUTES

Explanation

An OMEGAMON director did not detect a response from one of its associated collectors during the last 5 minutes.

System action

The director terminates this collector session.

User response

Determine why the collector failed, and restart the collector. If the condition continues, contact IBM Software Support.

OB0944 DIRECTOR INITIALIZATION FAILED: ID ALREADY IN USE

Explanation

An attempt to bring up an OMEGAMON director failed because OMEGAMON was already running in another address space using the same system ID (via the SYS= start-up keyword).

System action

OMEGAMON cancels the request.

User response

To initialize the OMEGAMON director, specify a unique value for the SYS= parameter.

OB0945 DIRECTOR INITIALIZATION FAILED: NOT AUTHORIZED

Explanation

An attempt was made to bring up an OMEGAMON director that did not have APF authorization.

System action

OMEGAMON terminates the director.

User response

APF authorize all of the necessary load libraries and restart the director.

OB0946 TARGET DIRECTOR NOT FOUND (RC=20)

Explanation

OMEGAMON could not start the requested OMEGAMON cross memory collector because it could not find the specified director (via the DIR= start-up keyword).

System action

OMEGAMON cancels the request.

User response

Bring up the OMEGAMON director before you try to initialize the collector or specify the ID of an active director.

OB0947 ANOTHER COLLECTOR HAS THE SAME ID (RC=24)

Explanation

An attempt to start the requested OMEGAMON collector failed because another collector was already active using the specified system ID (via the SYS= start-up keyword). You must specify a unique system ID for each collector when you bring up multiple OMEGAMON collectors in the same system.

System action

OMEGAMON cancels the request.

User response

Specify a unique system ID for each collector.

OB0948 INVALID NUMBER OF COLUMNS SPECIFIED (RC=36)

Explanation

The number of columns you specified (via the COLS= keyword) for the cross memory or cross system collector does not match the number of columns for the director with which the collector is attempting to begin a session.

System action

OMEGAMON cancels the request.

User response

Correct the COLS= value at either the collector or director and restart the session.

OB0949 DIRECTOR AT WRONG VERSION: CONNECTION FAILED (RC=40)

Explanation

A cross memory collector tried to start a cross memory session with an OMEGAMON director of a different and incompatible release level.

System action

OMEGAMON cancels the request.

User response

Bring up the director and cross memory collector using the same (or compatible) version of OMEGAMON.

OB0950 DISK DATA SET AT WRONG VERSION - REFORMAT (RC=40)

Explanation

This session’s cross system data set was formatted with an incompatible version of the format program.

System action

OMEGAMON cancels the request.

User response

Reformat the cross system data set with the current version of the KOBXDSK program.

OB0951 ONLY EIGHT SEGMENTS ALLOWED

Explanation

The /ATTACH command generates this message. OMEGAMON allows no more than 7 collectors plus the director segment at the director screen for cross memory/cross system mode terminal input/output processing.

System action

OMEGAMON cancels the request.

User response

If you need to display more than 7 collectors on this system, start another OMEGAMON director.

OB0952 COLLECTOR ID ALREADY ACTIVE

Explanation

The /ATTACH command generates this message. While trying to bring up a cross system collector session, OMEGAMON detected that this collector was already in session with a director.

System action

OMEGAMON cancels the request.

User response

Specify the correct collector ID.

OB0953 DDNAME MISSING

Explanation

This message may be issued in either of two situations:

  • When the /ATTACH command is issued and OMEGAMON did not find the correct DD statement for the cross system data set.
  • When attempting to start a collector and OMEGAMON did not find the correct DD statement for the cross system data set.

System action

OMEGAMON cancels the request.

User response

To correct the error, check the following:

  • A collector system ID for the session that matches the name specified on the SYS= start-up parameter.
  • A missing or incorrect DD statement in the director start-up JCL or EXEC file to point to the cross system data set.
  • A missing or incorrect DD statement in the collector start-up JCL or EXEC file to point to the cross system data set.

When you have corrected the error, restart the OMEGAMON director.

OB0954 COLLECTOR ID REQUIRED

Explanation

The /ATTACH command generates this message. An /ATTACH INFO-line command was entered without a collector ID.

System action

OMEGAMON cancels the request.

User response

Re-enter the /ATTACH command and specify a valid collector ID.

OB0955 DATA SET AT WRONG LEVEL - REFORMAT

Explanation

The /ATTACH command generates this message. A different release level format program was used to format the cross system data set for this cross system session and its director.

System action

OMEGAMON cancels the request.

User response

Reformat the cross system data set with the current version of the KOBXDSK program.

OB0956 DATA SET HAS WRONG NUMBER OF COLUMNS - REFORMAT

Explanation

The /ATTACH command generates this message. The cross system data set used for cross system session initialization was formatted for a different screen size (via the COLS= parameter) than that of the director terminal.

System action

OMEGAMON cancels the request.

User response

Reformat the cross system data set with KOBXDSK and specify the proper COLS= value.

OB0957 DIRECTOR MODE IS REQUIRED

Explanation

The /ATTACH command generates this message. The attempt to attach a cross system collector at an OMEGAMON console failed because it was not initiated as an OMEGAMON director.

System action

OMEGAMON cancels the request.

User response

Restart OMEGAMON, specifying the proper parameter for director mode.

OB0958 ENQUEUE ALREADY OUTSTANDING. QNAME: cccc

Explanation

An enqueue attempt by the director controller failed.

System action

The attach is suppressed.

User response

If this problem persists, contact IBM Software Support.

OB0959 DEQUEUE ATTEMPTED FOR RESOURCE NOT OWNED. QNAME:cccc

Explanation

A dequeue attempt by the director controller failed.

System action

The detach is suppressed.

User response

If this problem persists, contact IBM Software Support.

OB0960 BASE(Vnnnccc) AND INIT(Vnnnccc) VERSIONS ARE NOT COMPATIBLE

Explanation

You are using two incompatible levels of OMEGAMON load modules.

System action

OMEGAMON does not start.

User response

Verify that the proper libraries are in use. If necessary, reinstall OMEGAMON using the appropriate distribution tape.

OB0962 UNABLE TO OPEN PRIMARY CONSOLE

Explanation

OMEGAMON could not bring up the requested dedicated OMEGAMON session because the OMEGAMON console (specified by the UNIT= start-up keyword) is not available.

System action

If this is the first OMEGAMON console session in the address space, OMEGAMON terminates. Otherwise, the particular OMEGAMON console session terminates.

User response

Check to see whether the terminal address is attached to another user or owned by VTAM®. Specify an available console and retry.

OB0963 cc MODE INVALID: NOT A TSO SESSION

Explanation

You can only specify TS or LS mode at OMEGAMON start-up when OMEGAMON is running under a TSO session.

System action

OMEGAMON terminates.

User response

Correct the MODE= parameter and restart OMEGAMON.

OB0964 TS CHANGED TO LS AS THIS IS NOT A SCREEN DEVICE

Explanation

An OMEGAMON TSO session was altered to low-speed mode, since the OMEGAMON terminal is not a display device.

System action

TS mode becomes LS mode.

User response

Specify MODE=LS when starting OMEGAMON at this device.

OB0965 WARNING: NUMBER OF ROWS REQUESTED DOES NOT MATCH YOUR TERMINAL SIZE

Explanation

The value specified for the ROWS= start-up parameter does not match the actual size of the OMEGAMON terminal screen.

System action

OMEGAMON changes ROWS to match the terminal size; initialization continues.

User response

Specify a ROWS= value that matches your terminal’s physical characteristics at OMEGAMON start-up.

OB0966 RKOMPCSV DD CONCATENATED, UPDATES IGNORED

Explanation

The RKOMPCSV DD statement consists of more than one data set.

System action

MVS data management constraints prevent OMEGAMON from performing any PDS updates to RKOMPCSV. OMEGAMON ignores requests by the /SAVE and /REP INFO-line commands and the DELT and RENM immediate commands.

User response

Remove the concatenated data sets from the RKOMPCSV DD statement and restart OMEGAMON.

OB0967 xxPROCSV PRIOR SECURITY VIOLATION xxPROC —ABEND SX13

Explanation

A /SAVE or /REP command failed due to a security problem.

System action

The command terminates.

User response

Consult your security coordinator to gain access to the data sets in the xxPROC DD statement.

OB0969 INSUFFICIENT MEMORY TO INITIALIZE

Explanation

OMEGAMON was unable to GETMAIN enough virtual storage to complete initialization.

System action

Start-up fails.

User response

Increase the region size address space and restart OMEGAMON. (See message OB0970).

OB0970 INCREASE REGION SIZE BY nnnK AND RERUN

Explanation

Initialization failed because OMEGAMON needed additional virtual storage.

System action

OMEGAMON terminates.

User response

Increase the REGION= parameter by the amount that this message indicates and restart OMEGAMON. (See message OB0969.)

OB0971 ......+....1....+....2....+....3....+....4

Explanation

This ruler appears below message OB0972 to help you locate PARM line errors. The following additional message text displays below the ruler line, followed by the column location of the error, except when the error is in column 1.

System action

The OMEGAMON session terminates.

User response

Examine the message text and make suitable corrections. Additional message text:

  • OMEGAMON STARTUP PARAMETER ERROR
  • PARM FIELD SYNTAX ERROR
  • PARAMETERS MUST BE SEPARATED BY A COMMA
  • KEYWORD MUST END IN EQUAL SIGN
  • UNKNOWN KEYWORD PARAMETER
  • PARAMETER STRING TOO SHORT
  • PARAMETER STRING TOO LONG
  • PARAMETER NOT VALID HEXADECIMAL VALUE
  • PARAMETER VALUE TOO LOW
  • PARAMETER VALUE TOO HIGH
  • THIRD CHARACTER MUST BE NUMERIC
  • FIRST PARAMETER LENGTH ERROR
  • UNABLE TO ACQUIRE STORAGE FOR PARAMETER TABLES
  • UNIT SAME AS EXISTING TASK
  • OMEGAMON HAS PROBABLY BEEN ENTERED AS A TSO COMMAND
  • UNSUPPORTED MODE - BASE
  • UNSUPPORTED MODE - OMEGAMON
  • UNSUPPORTED MODE - NO IC DRIVER

OB0972 (USER INPUT APPEARS HERE)

Explanation

OMEGAMON issues this message with OB0971 (see above).

System action

OMEGAMON terminates.

User response

See the error code for OB0971.

OB0973 WARNING -- RUNNING nnn OMEGAMON ON yyy SYSTEM

Explanation

This level of OMEGAMON (nnn) is incompatible with this level of VM (yyy).

System action

OMEGAMON initialization continues, but with unpredictable results.

User response

If OMEGAMON did not terminate itself, stop it, install the correct OMEGAMON level, and restart OMEGAMON.

OB0974 aaaaaaaa LOADER ERROR

Explanation

OMEGAMON attempted to load module aaaaaaaa, but could not find it in the load library.

System action

The load fails and OMEGAMON issues an abend code 0974.

User response

Check that module aaaaaaaa is in the load library.

OB0975 aaaaaaaa MODULE HAS REENTRANT LINKAGE EDITOR ATTRIBUTE

Explanation

OMEGAMON could not update the module aaaaaaaa because it resides in a store-protected subpool.

System action

OMEGAMON terminates.

User response

Relink module aaaaaaaa without the RENT linkage editor parameter.

OB0976 RMF ASCB NOT FOUND

Explanation

OMEGAMON was unable to locate proper ASCB during RMF search.

System action

The process terminates.

User response

Contact IBM Software Support.

OB0977 {SMF|WTO} AUDITING IS BEING SUPPRESSED FOR THIS SESSION

Explanation

The user security exit has explicitly requested that SMF and/or WTO auditing be suppressed for this session; this request is made at initialization and/or relogon time. This message only appears once.

System action

The command terminates.

User response

None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.

OB0978 SECURITY ROUTINE HAS ABORTED STARTUP

Explanation

An external security routine passed back a non-zero return code to initialization.

System action

OMEGAMON terminates.

User response

See your security officer.

OB0979 ERROR LOADING PRODUCT MODULE cccccccc

Explanation

The product module could not be loaded successfully.

System action

OMEGAMON terminates.

User response

Be sure the named module is in the product library. See accompanying MVS system messages and take appropriate action. If it is not in the product library, contact IBM Software Support.

OB0980 SAVE STACK RECOVERY SUCCESSFUL

Explanation

The save area stack overflowed.

System action

The command terminates.

User response

Contact IBM Software Support.

OB0981 COMMAND TABLE ERROR cccc

Explanation

A validation error occurred while loading the command table module.

System action

OMEGAMON terminates.

User response

Contact IBM Software Support.

OB0982 ERROR DETECTED IN COMMAND TABLES

Explanation

An error occurred while loading the command tables.

System action

This is a secondary message. It follows messages that contain validation error information.

User response

Examine the previous errors and follow the recommended user responses.

OB0983 CANNOT LOCATE COMMAND TABLE MODULE, ABEND=cccc, RC=cc

Explanation

The usual cause of this message is insufficient region size for OMEGAMON to load the command table module.

System action

OMEGAMON aborts the session start.

User response

See your installer to increase the region size. For other possible causes, look up the abend code in the IBM System Codes manual for your system. You may also need to refer to the IBM System Messages manual.

OB0984 NO COMMAND TABLE MODULE NAME

Explanation

An error occurred in command table processing.

System action

OMEGAMON terminates.

User response

Contact IBM Software Support.

OB0985 SAVE STACK RECOVERY SUCCESSFUL

Explanation

Invalid stack release by a command.

System action

OMEGAMON terminates the command execution.

User response

This is an internal error. Contact IBM Software Support.

OB0986 GETMAIN FAILED FOR COMMAND TABLES

Explanation

The request for storage for a copy of the command module failed.

System action

OMEGAMON terminates.

User response

Increase the region size for OMEGAMON.

OB0987 PRODUCT INITIALIZATION FAILED, RC=nnn

Explanation

The product initialization routines have returned an error code which is non-zero.

System action

OMEGAMON terminates.

User response

Read any other messages that accompany this message. If unable to find the problem, contact IBM Software Support.

OB0988 PRODUCT LEVEL nnn INCOMPATIBLE WITH DRIVER LEVEL mmm

Explanation

The base driver module cannot service the current product.

System action

OMEGAMON initialization stops.

User response

Use a base driver which is at the same or greater level than the product you are trying to initialize. Retry using this new driver.

OB0989 KOBCICSUSERcc MUST BE REASSEMBLED; IT IS NOT COMPATIBLE WITH THIS RELEASE OF OMEGAMON

Explanation

The user assembled an old KOBCICSUSER module that is incompatible with the current release of OMEGAMON.

System action

OMEGAMON initialization stops.

User response

Obtain the current KOBCICSUSER from the product tape and reassemble.

OB0990 SECURITY LOGGING, userid, cccccccc, ACCESS(aaaaaaaa)

Explanation

The security settings of the command table produce this security logging message. The variable cccccccc is the command being validated and aaaaaaa is the result. The userid is displayed if AUDIT=WTO is specified.

System action

OMEGAMON terminates execution of any command to which it denies access.

User response

None. This is an informational message and does not require further action. Typically, this type of message clarifies some aspect of system behavior during normal operations.

OB0991 DYNAMIC ALLOCATION ERROR: ERROR=cccc, INFO=cccc

Explanation

A dynamic allocation request failed with the ERROR and INFO codes indicated.

System action

The allocation process terminates.

User response

Examine the error and information codes in the message and take appropriate action.

OB0992 aaUSERbb VALIDATION FAILED. RC=n

Explanation

The user profile aaUSERbb did not pass product validation.

System action

Session initialization terminates.

User response

If other messages were issued previously, take the action suggested for those messages. If no other messages were issued, contact IBM Software Support.

OB0993 NO ARGUMENT HAS BEEN SUPPLIED

Explanation

A valid argument was not supplied for the command.

System action

The command terminates.

User response

Supply a valid argument and reissue the command.

OB0994 NO VALID PATTERN HAS BEEN SUPPLIED

Explanation

A valid pattern was not supplied for the command.

System action

The command terminates.

User response

Supply a valid pattern and reissue the command.

OB0995 UNABLE TO LOG AUDIT RECORD TO SMF, RC=cc

Explanation

A non-zero return code was received from SVC 83 while attempting to track an audited command. These codes are documented in the IBM System Programming Library: System Management Facilities (SMF) manual for your system.

System action

A WTO is issued to the console with audit information.

User response

Consult the appropriate IBM documentation for an explanation and interpretation of the non-zero return code. This return code may indicate a serious problem with SMF.

OB0996 APF AUTHORIZATION REQUIRED FOR SMF LOGGING

Explanation

OMEGAMON cannot write SMF records unless it is APF-authorized. This message will appear only once; thereafter, all audit activity will be directed to the console for the duration of the session.

System action

A WTO is issued to the console with audit information.

User response

Determine whether OMEGAMON should be authorized. This is an installation decision.

OB0997 RECORD NUMBER MUST BE BETWEEN 128 AND 255 (INCLUSIVE) FOR SMF LOGGING

Explanation

OMEGAMON detected a request to write an SMF record with an invalid record ID. User SMF records must use a record ID between 128 and 255, inclusive. This message will appear only once; thereafter, all audit activity will be directed to the console for the duration of the session.

System action

A WTO is issued to the console with audit information.

User response

Use the Security Update Program to specify a valid SMF record ID.

OB0998 EXTERNAL SECURITY IS UNAVAILABLE

Explanation

OMEGAMON could not locate the user security routine to process a command for which external security was requested. Internal security was not invoked because the command did not have a security level associated with it.

System action

OMEGAMON suppresses command execution.

User response

Determine why the user security routine is missing. Make sure it is in a link-list library or in the OMEGAMON STEPLIB.

OB1112 DATA COLLECTOR IS NOT ACTIVE

Explanation

The requested collector is not currently active.

System action

The IPRO command processor suppresses the display.

User response

Start the collector and retry the command.