KOBRR0033I After CELQPIPI init_sub CELQPIPI=address TOKEN=token RC=return-code

Explanation

The Tivoli OMEGAMON Manager (TOM) address space called the z/OS Language Environment® CELQPIPI init_sub function, but the call ended with a non-zero return code return-code.

System action

Processing continues. Some TOM functionality might not work. The TOM log might contain subsequent error messages with additional details.

User response

If the return-code value is 8 or 32, the TOM was unable to load one or both of load modules KOBRES01 and KOBSRT01. This error can occur if the TOM runtime environment installation (or upgrade) was incomplete or unsuccessful. Check that the TKANMODP load library in the TOM STEPLIB concatenation contains both of these modules and that both of them are AMODE 64. If additional assistance is needed, collect the TOM log and contact IBM Software Support.

For other return-code values, collect the TOM log and contact IBM Software Support.