KOBOD0010E The requested application product ID, applid, is not a registered application.

Explanation

A request for the Object Definition Interchange (ODI) information was received for an application product that is not registered with the OMEGAMON Enhanced 3270 user interface.

System action

The ODI Loader subcomponent stops processing the request and returns an error return code.

User response

The ODI cache is maintained in 64-bit virtual storage. Verify that the address space has been given sufficient storage to use for the ODI cache. Verify that the runtime environment was copied correctly. Also, check that the ODI is referenced in the KOBCFGAP and KOBREGAP members of the data set that is referenced in the RKANPAR DDNAME concatenation list. If the members are present and the ODI is correctly referenced, but the problem persists, contact IBM Software Support.
Capture the following diagnostic information:
  • The OMEGAMON Enhanced 3270 user interface SYSPRINT log file
  • A directory listing of the data sets referenced by the OMEGAMON Enhanced 3270 user interface RKANDATV DD name
  • A listing of the content for the members KOBCFGAP and KOBREGAP of the data set or data sets referenced in the RKANPAR DDNAME concatenation list