KFASD005 Detected that the catalog is missing for product <variable> version <variable> id <variable> id version <variable>. Catalog version was <variable>,<variable>, state <variable>, status <variable>.

Explanation

During startup, the Tivoli Enterprise Monitoring Server (TEMS) determined that the catalog for an installed product was removed. The most common status codes (the value of the STATUS column in the TAPPLPROPS table) and their descriptions are:
0
Operation successful
1001
Request queued
1002
Out of memory
1003
Bad argument
1004
Not found
1005
System error
1006
Request for same product already in progress or queued
1007
KT1 error
1008
Self-Describing Agent (SDA) feature disabled at TEMS
1009
Hub not there
1010
TEMS shutdown in progress
1011
Invalid content in manifest file
1012
Wrong TEMS version
1013
Unsupported feature
1014
Unknown error
1015
Bad input argument
1016
Record updated by the manual install detection process
1017
Temp install error, agent expected to retry install request
1018
Error refreshing catalog files
1019
Error refreshing attribute files
1020
Error refreshing Omegamon2TEC files
1021
Time expired waiting for SDA install completion
1022
Seeding error
1023
SDA not initialized due to config error

System action

None.

User response

If the specified product is still in use, manually reinstall the support files and restart the Tivoli Enterprise Monitoring Server. Otherwise, no action is required.