Kpp_X_AGT_CONFIRM_SHUTDOWN
Use this parameter to specify the maximum number of seconds between two successive
SHUTDOWN
commands or MVS STOP (P)
commands to terminate the
monitoring agent address space.
- Required or optional
- Required
- Location where parameter value is stored
- In the KPPSYSIN member of the rhilev.midlev.rtename.RKANPARU
library
- Parameter name
CONFIRM(&XPPFIRM)
(Confirm shutdown option)- Default value
- 0
- Permissible values
- 0 to 15
- PARMGEN name
- KPP_X_AGT_CONFIRM_SHUTDOWN
- PARMGEN classification
- Additional agent settings
- Description
-
Confirm shutdown option
This parameter sets the maximum number of seconds between two successive
SHUTDOWN
commands orMVS STOP (P)
commands to terminate the monitoring agent address space.CONFIRM(0) allows TMS:Engine shutdown to begin immediately without an additional, confirming SHUTDOWN command.
CONFIRM(n) prevents accidental shutdowns by requiring you to confirm the command by entering it a second time within the specified number of seconds.
For example, CONFIRM(15) requires you enter SHUTDOWN twice within 15 seconds to terminate the address space.
The default for the monitoring agent CONFIRM is 0, which is also the Tivoli® Enterprise Monitoring Server default.
- Related parameters
- None