Kpp_X_AGT_CONFIRM_SHUTDOWN

Use this parameter to specify the maximum number of seconds between two successive SHUTDOWN commands or MVS STOP (P) commands to terminate the monitoring agent address space.

Required or optional
Required
Location where parameter value is stored
In the KPPSYSIN member of the rhilev.midlev.rtename.RKANPARU library
Parameter name
CONFIRM(&XPPFIRM) (Confirm shutdown option)
Default value
0
Permissible values
0 to 15
PARMGEN name
KPP_X_AGT_CONFIRM_SHUTDOWN
PARMGEN classification
Additional agent settings
Description

Confirm shutdown option

This parameter sets the maximum number of seconds between two successive SHUTDOWN commands or MVS STOP (P) commands to terminate the monitoring agent address space.

CONFIRM(0) allows TMS:Engine shutdown to begin immediately without an additional, confirming SHUTDOWN command.

CONFIRM(n) prevents accidental shutdowns by requiring you to confirm the command by entering it a second time within the specified number of seconds.

For example, CONFIRM(15) requires you enter SHUTDOWN twice within 15 seconds to terminate the address space.

The default for the monitoring agent CONFIRM is 0, which is also the Tivoli® Enterprise Monitoring Server default.

Related parameters