Completing the upgrade

After you have completed the configuration steps for the appropriate upgrade scenario, there are additional steps you may need to complete.

OMEGAMON enhanced 3270 user interface
If you are enabling the enhanced 3270 user interface for the first time, the following steps must be completed:
  1. Define the new started task user IDs to your STC table. The default name is IBMTOM.
  2. Define the new VTAM APPLID for the enhanced user interface. The default name is CTDOBAP.
  3. APF-authorize &rte_hilev.&rte_name.RKANMODP library, as this load library is included in the STEPLIB DDNAME of all started tasks.
  4. Customize the KOB* parameters as desired.
  5. Add the new address space to the system PROCLIB and add its VTAM major node to the system VTAMLST. If you are using a global VTAM major node, refresh the global VTAM major node with the user interface's VTAM LOGON APPLID.

    In PARMGEN, the KCIJPSYS job is available to perform these steps.

In a PARMGEN upgrade, steps 1-3 are done automatically (and step 5 if the KCIJPSYS job is run).