KN3_AGT_KLX_TCP_TOLERATERECYCLE
Use the KN3_AGT_KLX_TCP_TOLERATERECYCLE parameter to determine whether the monitoring agent address space reconnects to its TCP/IP stack without being recycled after the stack is recycled.
- Required or optional
- Optional
- Location where the parameter value is stored
- In the KN3INTCP member of the rhilev.midlev.rtename.RKANPARU
library
- Parameter name
TCP/IP_USERID=’&tcpip_stc’ TOLERATERECYCLE
(Reconnect after TCP/IP recycle)- Default value
- N
- Permissible values
- Y or N
- Batch parameter name
- KN3_AGT_KLX_TCP_RECYCLE
- PARMGEN name
- KN3_AGT_KLX_TCP_TOLERATERECYCLE
- PARMGEN classification
- Advanced Agent configuration values
- Description
-
Reconnect after TCP/IP recycle
The parameter determines whether the monitoring agent address space reconnects to its TCP/IP stack without being recycled after the stack is recycled. Set this parameter to Y to allow the monitoring agent address space to reconnect to the z/OS® Communications Server without having to subsequently recycle the address space. When this parameter is set to Y, the "TOLERATERECYCLE" keyword is added in the KN3INTCP member of the RKANPARU library. The parameter line is generated as:
TCP/IP_USERID=&tcp_userid TOLERATERECYCLE
.If this parameter is set to N, when the z/OS Communications Server is recycled, the monitoring agent address space must also be recycled to establish connectivity to TCP/IP. The default is N for the Configuration Tool and TOLERATERECYCLE (meaning yes) for PARMGEN.
Note: This parameter may be specified only when the monitoring agent is reporting to Tivoli® Enterprise Monitoring Server V6.2.0 and later versions. - Related parameters
- None