Configuring the RESTART parameter

You can use the RESTART parameter to start the OMEGAMON for IMS Classic Realtime Monitor. The optional RESTART parameter forces the subsystem to complete initialization and bypass checks that are designed to prevent the start of a second address space. Use the RESTART parameter only if the subsystem address space ends abnormally.

Before you begin

When you attempt to start the subsystem, message CNDL018I displays. Message CNDL018I indicates that the subsystem is already active. Verify that the subsystem address space is not active before you use RESTART. If you use RESTART when the subsystem is already active, results are unpredictable.

Procedure

Issue the FORCE operand with the RESTART parameter, as shown in the following example:
where IBMCN is the name of the subsystem startup procedure.
START IBMCN,RESTART=',RESTART=FORCE'