KI5_X_AGT_CONFIRM_SHUTDOWN

Use the KI5_X_AGT_CONFIRM_SHUTDOWN parameter to end the OMEGAMON® for IMS on z/OS address space. You can specify the maximum number of seconds between two successive SHUTDOWN commands or between MVS STOP (P) commands.
Required or optional
Required
Location where the parameter value is stored
The KI5SYSIN member of the rhilev.midlev.rtename.xKANPARU library where x is R, W, or I.
Parameter name
CONFIRM(&XI5FIRM)
Default value
0
Permissible values
0 - 15

The CONFIRM(0) parameter allows the TMS:Engine to shut down immediately without requiring an extra, confirming SHUTDOWN command. The CONFIRM(n) parameter prevents accidental shutdowns by requiring you to reenter the command within the specified number of seconds. For example, CONFIRM(15) requires you to enter SHUTDOWN twice within 15 seconds to terminate the address space.