Secondary console control
If you run OMEGAMON® for IMS in dedicated mode, you can set up a secondary console for output display only. The secondary console is a repeater console; it echoes everything that appears on the primary console, but accepts no input of any kind.
To use a secondary console, first define the unit, and then open
it up for OMEGAMON for IMS output display.
To define the console, enter the .CNxxx
immediate
command, where xxx is the hexadecimal address of the secondary console.
Then, enter .CN OP
to open the console for OMEGAMON for IMS output display. The secondary
console, like the dedicated console, must be a non-SNA local device.
To close a secondary console, enter the .CN CL
command.
You can also enter the .CN SW
command to switch the
primary and secondary console functions.