Check the OMEGAMON® Collector started task SYSPRINT output to verify
that the server accepted your parameters.
Before you begin
Before you test the setup of the OMEGAMON Collector, ensure you have
completed the product setup, so that you can start the OMEGAMON Collector.
Procedure
-
Start the OMEGAMON Collector.
-
Review the SYSPRINT output of the OMEGAMON Collector started task in
SDSF. Verify that the following outputs match the parameters you specified:
-
TCP/IP.
-
IP ADDRESS OF SERVER INSTANCE.
If you left the IP address blank because your host only has one IP address, you will see
0.0.0.0 here.
-
MAXIMUM NUMBER OF PARALLEL SESSIONS.
-
TCPNAME (this value is not of interest for end-to-end SQL or stored procedure monitoring).
-
DATASHARINGGROUP.
-
TCPIP PORT.
- Verify that the last output is FPEV1330I, TCP/IP
SERVER TASK STARTED.
This means that the TCP/IP port opened
successfully.