KD5_DBnn_SS_GBPSTAT

GBP Coupling facility interval

Description

This specifies the interval, in seconds, that Coupling Facility structure statistics for Group Buffer Pools will be collected. The default collection interval is 600 seconds.

To disable collection of these statistics, set this field to 0.

Required or optional
Optional
Default value
600
Minimum
0
Maximum
999
Location where the parameter value is stored
In the KDPCNFG member of the rhilev.midlev.rtename.RKANPARU library
Output line
GBPSTAT(<value>)
In the Configuration Tool (ICAT)
Panel 1
Panel name
SPECIFY DB2 DATA COLLECTOR OPTIONS
Panel ID
KD541P3
Panel field
Group Buffer pool statistics
Panel 2
Panel name
SPECIFY DB2 DATA COLLECTOR OPTIONS
Panel ID
KD541P3A
Panel field
Group Buffer pool statistics
Default value
600
Minimum
0
Maximum
999
Batch parameter name
KD5_DB_SS_GBPSTAT
PARMGEN name
KD5_DBnn_SS_GBPSTAT
PARMGEN classification
Agent