KD2_OMPE_RUNALLOC
Automatic submit of allocation job
- Description
-
Specify whether the 'Create DB2 related runtime members' job should trigger that the 'Allocate runtime datasets' job is submitted. The data set allocation job takes care of allocating all operational data sets required for the enabled functions, for example to collect data for Near-Term History. This job does not overwrite existing operational data sets.
- Required or optional
- Required
- Default value
- Y
- Permissible values
- Y, N
- Locations where the parameter value is stored
-
- Location 1
- In the CRTDB2 member of the rhilev.midlev.rtename.RKD2SAM library
- Output line
-
<value> +
- Location 2
- In the CRTDB2M member of the rhilev.midlev.rtename.RKD2PRF library
- Output line
-
<value> +
- In the Configuration Tool (ICAT)
-
- Panel name
- Global Control Parameters
- Panel ID
- KD261PI
- Panel field
- Automatic submit of runtime dataset allocation job
- Default value
- N
- Permissible values
- Y, N
- Batch parameter name
- KD2_OMPE_RUNALLOC
- PARMGEN name
- KD2_OMPE_RUNALLOC
- PARMGEN classification
- OMPE