KD2_OMPE_CCPC_TIMER

TEMA connection timeout interval

Description

This timeout interval is used to control the amount of time that a TEMA connect or TEMA collect call remains pending while collecting the data from a target DB2 subsystem is not completed. The TEMA is notified when the call exceeds the specified timeout interval. Specify a value in the range of 0010-0300. 0010 represents ten seconds and 0300 represents three minutes.

Required or optional
Required
Default value
0030
Minimum
0010
Maximum
0300
Locations where the parameter value is stored
Location 1
In the OMPECCPC member of the rhilev.midlev.rtename.RKD2PAR library
Output line
START COMMCOLL,PARM=(TRACE=YES,STIMER=00<value>.00,SLX=REUSE)
Location 2
In the OMPECCPC member of the rhilev.midlev.rtename.RKD2PAR library
Output line
START COMMCOLL,PARM=(TRACE=NO,STIMER=00<value>.00,SLX=REUSE)
In the Configuration Tool (ICAT)
Panel name
OMEGAMON Collector Information
Panel ID
KD261PN
Panel field
TEMA connection timeout interval
Default value
0030
Minimum
0010
Maximum
0300
Batch parameter name
KD2_OMPE_CCPC_TIMER
PARMGEN name
KD2_OMPE_CCPC_TIMER
PARMGEN classification
OMPE