KD2_OMPE_CCPC_TIMER
TEMA connection timeout interval
- Description
-
This timeout interval is used to control the amount of time that a TEMA connect or TEMA collect call remains pending while collecting the data from a target DB2 subsystem is not completed. The TEMA is notified when the call exceeds the specified timeout interval. Specify a value in the range of 0010-0300. 0010 represents ten seconds and 0300 represents three minutes.
- Required or optional
- Required
- Default value
- 0030
- Minimum
- 0010
- Maximum
- 0300
- Locations where the parameter value is stored
-
- Location 1
- In the OMPECCPC member of the rhilev.midlev.rtename.RKD2PAR library
- Output line
-
START COMMCOLL,PARM=(TRACE=YES,STIMER=00<value>.00,SLX=REUSE)
- Location 2
- In the OMPECCPC member of the rhilev.midlev.rtename.RKD2PAR library
- Output line
-
START COMMCOLL,PARM=(TRACE=NO,STIMER=00<value>.00,SLX=REUSE)
- In the Configuration Tool (ICAT)
-
- Panel name
- OMEGAMON Collector Information
- Panel ID
- KD261PN
- Panel field
- TEMA connection timeout interval
- Default value
- 0030
- Minimum
- 0010
- Maximum
- 0300
- Batch parameter name
- KD2_OMPE_CCPC_TIMER
- PARMGEN name
- KD2_OMPE_CCPC_TIMER
- PARMGEN classification
- OMPE