Exception event notification is started from the Exception Processor panel under
Activate/Deactivate Exception Processing.
The Exception Processor panel is shown in Figure 1.Figure 1. Exception Processor panel
DGOMEP02 Exception Processor PMO1DLOC DSN1 V10
For any field enter any character to activate
More: - +
Activate/Deactivate Exception Processing
_ Periodic > User Exit
_ Exception event notification
Options
Periodic units . . . . . . . . . . . . . . 2 1=Seconds
2=Minutes
Periodic interval . . . . . . . . . . . . 10 1-7200 Seconds
1-120 Minutes
> Disable auto-display for problem exceptions
> Sound alarm for exception warnings
_ Log file data set output needed
_ DPMOUT data set output needed
Exception threshold data set
Name . . . . . . . . . ________________________________________________
Command ===> _______________________________________________________________
F1=Help F2=Split F3=Exit F7=Up F8=Down F9=Swap
F12=Cancel F16=Look F17=Collect
Enter any character in the Exception event notification field to activate
exception event notification.
The events must be specified with the EVENTOBSERVATION data collector parameter or from the
Data Collector Parameters window of the administrator user dialog before exception event
processing can be activated.