FPEV0559I <V1> HISTORY MANAGER RETURN AREA TOO SMALL. DATA TRUNCATED
Explanation
The OMEGAMON for Db2
PE
Db2 IFI return area is not large enough to store all the
returned Db2 data for a history manager IFI READS request.
Some data got lost. This can happen if you are requesting a data sharing group wide snapshot of
the whole data sharing group for history saving.
- <V1> is the Db2 subsystem ID.
User response
None required. However, you can limit
the amount of data requested from Db2 by
using the Configuration Tool (formerly ICAT) and specifying one or
more history qualifiers (HQx) as Data Server startup parameters.
For example, the specification of HQ1=(PL=CICS*,PL=MANUFACT,PL=HR*)
invokes
multiple IFI READS requests. However, depending on the number of history
qualifiers (HQx) and how you specify them, a thread can match
more than one qualification, multiple thread data can be collected,
and problems can occur when past data is viewed.