FPEV0522I <V1> HISTORY DATA SET SIZE IS TOO SMALL

Explanation

The OMEGAMON® Collector detected that the size of the history data set, specified in the SHDATASETSIZE startup parameter, is too small to store even two logical snapshots (intervals). The message continues to be repeatedly issued, and an entry is written to the OMEGAMON Collector SYSPRINT log, each time after one current interval is stored. When further storing is not possible because of the size limitation, the History Manager task stops to avoid a corruption of the data and indexes in the history data set.
  • <V1> is the Db2 subsystem ID.

User response

Use the Configuration Tool (formerly ICAT) and increase the SHDATASETSIZE startup parameter value to a reasonable size, based on the recommendations given in Installation and Configuration and the statistics provided by message FPEV0511I. Reallocate the history data set, changing its size so that it corresponds with the value specified in SHDATASETSIZE.