FPEV0221W <V1> COMMAND FAILED. THE DATA SERVER INSTANCE FOR THE SPECIFIED Db2 SUBSYSTEM <V2> IS NOT RUNNING.

Explanation

The subtask command issued to the PE Server subtask (PESERVER) failed because the server instance for the specified Db2 subsystem is not running.

Possible reasons that the server instance failed include the following:
  • the PE Server subtask was not started because the Data Server is not configured to start monitoring for the specified Db2 subsystem.
  • the PE Server subtask terminated because the Db2 subsystem terminated.
  • the PE Server subtask ended abnormally.

<V1>is the name of the master controller inside the OMEGAMON® Collector (MSTR).

<V2> is the Db2 subsystem identifier.

User response

Verify that the PE Server subtask is configured to monitor the specified Db2 subsystem and that the Db2 subsystem is running. Restart the PE Server subtask and reissue the command.