Check the OMEGAMON Collector started
task SYSPRINT output to verify that the server accepted your parameters.
Before you begin
Before you test the setup of the OMEGAMON® Collector, ensure you have completed
the product setup, so that you can start the OMEGAMON Collector.
Procedure
- Start the OMEGAMON Collector.
- Review the SYSPRINT output of the OMEGAMON Collector started task in SDSF.
Verify that the following outputs match the parameters you specified:
- TCP/IP.
- IP ADDRESS OF SERVER INSTANCE.
If you left
the IP address blank because your host only has one IP address, you
will see 0.0.0.0 here.
- MAXIMUM NUMBER OF PARALLEL SESSIONS.
- TCPNAME (this value is not of interest for end-to-end SQL or stored procedure monitoring).
- DATASHARINGGROUP.
- TCPIP PORT.
- Verify that the last output is FPEV1330I, TCP/IP
SERVER TASK STARTED.
This means that the TCP/IP port opened
successfully.