KD2_PFnn_SH_D2SHSTAI
Statistics interval
- Description
-
Specifies in seconds how often the OMEGAMON Collector is to collect statistics data for later viewing. This value can be set from 1 second to 86400 seconds for one day.
- Required or optional
- Optional (Required in case KD2_PF_SH_D2SHKHST is set to Y and KD2_PF_SH_D2SHSTAT is set to Y)
- Default value
- 120
- Minimum
- 1
- Maximum
- 86400
- Location where the parameter value is stored
- In the OMPEssid member of the rhilev.midlev.rtename.RKD2PAR library
- Output line
-
SHSTATISTICS=(<KD2_PFnn_SH_D2SHSTAT>,<value>)
- In the Configuration Tool (ICAT)
-
- Panel name
- Snapshot History
- Panel ID
- KD261PE
- Panel field
- Statistics Interval
- Default value
- 120
- Minimum
- 1
- Maximum
- 86400
- Batch parameter name
- KD2_PF_SH_D2SHSTAI
- PARMGEN name
- KD2_PFnn_SH_D2SHSTAI
- PARMGEN classification
- SS_HIS