KD2_PFnn_HIS_SEQ_SECONDARY_CYL

Secondary space for sequential datasets

Description

Specify the secondary space allocation used for the sequential datasets. The default is 2 cylinders.

This field is only applicable if the storage type is VSAMSEQ, VSAMSEQTHVSAM, SEQTHVSAM and the storage mechanism is STATIC SEQUENTIAL.

Required or optional
Optional (Required in case KD2_PF_HIS_START is set to C,Y and KD2_PF_HIS_SEQ_TYP is set to S)
Default value
2
Minimum
0
Maximum
9999
Locations where the parameter value is stored
Location 1
In the ALLOCDS member of the %RTE_HILEV%.%RTE_NAME%.RKD2SAM library
Output line
DSORG(PS) SPACE(<KD2_PFnn_HIS_SEQ_PRIMARY_CYL> <value>) CYLINDERS
Location 2
In the COPTssid member of the %RTE_HILEV%.%RTE_NAME%.RKD2PAR library
Output line
SPACE(CYL,<KD2_PFnn_HIS_SEQ_PRIMARY_CYL>,<value>)
PARMGEN name
KD2_PFnn_HIS_SEQ_SECONDARY_CYL
PARMGEN classification
NTH