KD2_PFnn_HIS_SEQ_LOG_NUM
Number of NTH static SEQ data sets
- Description
-
Specify the number of sequential data sets that will be created for trace data collection. A minimum of 3 data sets is required. Ensure that the set of historical sequential data sets is unique for each Db2 subsystem.
This field is only applicable if the storage type is VSAMSEQ, VSAMSEQTHVSAM, SEQTHVSAM and the storage mechanism is STATIC SEQUENTIAL.
- Required or optional
- Optional (Required in case KD2_PF_HIS_START is set to C,Y and KD2_PF_HIS_SEQ_TYP is set to S)
- Default value
- 3
- Minimum
- 3
- Maximum
- 10
- Locations where the parameter value is stored
-
- Location 1
- In the ALLOCDS member of the rhilev.midlev.rtename.RKD2SAM library
- Output line
-
LISTCAT ENTRIES('<value>') NAME
- Location 2
- In the ALLOCDS member of the rhilev.midlev.rtename.RKD2SAM library
- Output line
-
ALLOC DSNAME('<value>') -
- In the Configuration Tool (ICAT)
- This value cannot be updated using the Configuration Tool.
- Batch parameter name
- KD2_PF_HIS_SEQ_LOG_NUM
- PARMGEN name
- KD2_PFnn_HIS_SEQ_LOG_NUM
- PARMGEN classification
- NTH