KD2_OMPE_OPTS_NTHDB2I

NTH Collector Db2 initialization option

Description

This parameter controls the behavior of NTH collection task during startup with regards to Db2 subsystem availability.

When set to WTOR (the default), a WTOR will be issued which the user can reply to and have NTH collection changed to a different Db2 subsystem or to stop the NTH collection task.

If no reply is given to the WTOR, the WTOR will be deleted when the Db2 subsystem is discovered/started or when the started task is shut down.

If set to WAIT, then the NTH collector waits until the Db2 subsystem is started.

Required or optional
Optional
Default value
WTOR
Permissible values
WTOR, WAIT
Location where the parameter value is stored
In the OMPEOPTS member of the rhilev.midlev.rtename.RKD2PAR library
Output line
NTHDB2I=<value>
In the Configuration Tool (ICAT)
This value cannot be updated using the Configuration Tool.
Batch parameter name
KD2_OMPE_OPTS_NTHDB2I
PARMGEN name
KD2_OMPE_OPTS_NTHDB2I
PARMGEN classification
OMPE