KD2_PFnn_OA_INTV
Object analysis collection info
- Description
-
This specifies the time interval in minutes for the object analysis and the volume analysis collectors. The interval may be from 1 to 1440 minutes.
- Required or optional
- Optional (Required in case KD2_PF_OA_START is set to Y)
- Default value
- 15
- Minimum
- 1
- Maximum
- 1440
- Location where the parameter value is stored
- In the OMOAssid member of the rhilev.midlev.rtename.RKD2PRF library
- Output line
-
F EVENTMGR,START DB2=%DB%,INTERVAL=<value>,THREAD=&THREAD
- In the Configuration Tool (ICAT)
-
- Panel name
- Object and Volume Analysis
- Panel ID
- KD261PM
- Panel field
- Object analysis collection interval
- Default value
- 15
- Minimum
- 1
- Maximum
- 1440
- Batch parameter name
- KD2_PF_OA_INTV
- PARMGEN name
- KD2_PFnn_OA_INTV
- PARMGEN classification
- OBJ_ANAL