KD2_OMPE_SUB_D2PASSIT

SSI timer value SSITIMER

Description

Defines the subsystem interface SSI loop detection timer in seconds. You can specify a timer in the range of 1 to 99 seconds. This timer value is used by the OMPE subsystem timer services component to measure the elapsed time an SSI function routine EOT, EOM, CMD, WTO executes. When the specified timer value is exceeded, the SSI broadcast function is abnormally terminated.

Required or optional
Required
Default value
30
Minimum
1
Maximum
99
Location where the parameter value is stored
In the OMPE00 member of the rhilev.midlev.rtename.RKD2PAR library
Output line
SSITIMER=<value>
In the Configuration Tool (ICAT)
Panel name
OMEGAMON Collector Subsystem Information
Panel ID
KD261PA
Panel field
SSI timer value
Default value
30
Minimum
1
Maximum
99
Batch parameter name
KD2_OMPE_SUB_D2PASSIT
PARMGEN name
KD2_OMPE_SUB_D2PASSIT
PARMGEN classification
DB2