KD2_PFnn_AEXCP_D2TPTDSN
Threshold data set name
- Description
-
The Exception Threshold data set contains the exception thresholds for the Statistics and Accounting exception reports and traces. When exception processing is active, the instrumentation data is checked against these thresholds.
You can either use an existing threshold data set or let ICAT generate a new threshold data set. Specify a fully qualified data set name without quotes. If the specified threshold data set does not exist, ICAT generates an empty sequential data set using the following attributes:
- RECFM
- VB
- LRECL
- 255
- BLKSIZE
- 6233
You need to specify thresholds in the specified data set. If the threshold data set is empty, Automatic Exception Processing is not started and the following message is written to the message log:
FPEV0263E D823 AUTOMATIC EXCP NOT STARTED - NO VALID THRESHOLD
To specify thresholds:
Use the thresholds in the supplied sample Threshold data set DGOETV41 in RKO2DATA or in case of an SMP/E Sharing RTE: TKO2DATA. The sample contains a selection of exception fields with predefined threshold values and can be used to get started with exception reporting. To use the sample threshold data set as input for Automatic Exception Processing, copy the contents of DGOETV41 to the threshold data set generated by ICAT.
Note: The sample Exception Threshold data set member DGOETV41 has a different record length. As a result, when you copy member DGOETV41 to your newly allocated data set, you see a warning that records are truncated. You can ignore this warning.
Refer to the Reporting User's Guide 'Specifying exceptions using the Exception Threshold data set editor' and 'Exception Threshold data set' for additional information.
- Required or optional
- Optional (Required in case KD2_PF_AEXCP_D2PYACT is set to Y)
- Default value
- %RTE_HILEV%.%RTE_NAME%.RKD2THRS
- Locations where the parameter value is stored
-
- Location 1
- In the OMPEssid member of the rhilev.midlev.rtename.RKD2PAR library
- Output line
-
AUTOEXCPTHNAME=<value>
- Location 2
- In the ALLOCDS member of the rhilev.midlev.rtename.RKD2SAM library
- Output line
-
DSNAME('<value>') -
- Location 3
- In the ALLOCDS member of the rhilev.midlev.rtename.RKD2SAM library
- Output line
-
ENTRIES('<value>') -
- In the Configuration Tool (ICAT)
-
- Panel name
- Periodic Exception Processing
- Panel ID
- KD261PY
- Panel field
- Threshold data set name
- Default value
- None
- Batch parameter name
- KD2_PF_AEXCP_D2TPTDSN
- PARMGEN name
- KD2_PFnn_AEXCP_D2TPTDSN
- PARMGEN classification
- EXCP