KD2_PFnn_DCM_D2SHDCSI
DB2 Connect system data
- Description
-
Specifies in seconds how often the OMEGAMON Collector is to collect DB2 Connect system data for later viewing. This value can be set from 10 second to 86400 seconds for one day. It is recommended to set this value to a multiple of KD2_PFnn_SH_D2SHSTAI.
- Required or optional
- Optional (Required in case KD2_PF_SH_D2SHKHST is set to Y and KD2_PF_DCM_D2SHDCST is set to Y)
- Default value
- 120
- Minimum
- 10
- Maximum
- 86400
- Location where the parameter value is stored
- In the OMPEssid member of the rhilev.midlev.rtename.RKD2PAR library
- Output line
-
SHDB2CONNECTSYSTEM=(<KD2_PFnn_DCM_D2SHDCST>,<value>)
- In the Configuration Tool (ICAT)
-
- Panel name
- Snapshot History
- Panel ID
- KD261PE
- Panel field
- DB2 Connect System Interval
- Default value
- 120
- Minimum
- 10
- Maximum
- 86400
- Batch parameter name
- KD2_PF_DCM_D2SHDCSI
- PARMGEN name
- KD2_PFnn_DCM_D2SHDCSI
- PARMGEN classification
- SS_HIS