Region and Program Information
This panel displays information available from the private area.
________________ ZPEEKAE VTM O2 V540.#P DA41 11/06/13 11:18:35 2
> Help PF1 Back PF3 Up PF7 Down PF8
> M.A.E
> SYSTEM SERVICES ADDRESS SPACE: Enter a selection letter on the top line.
> A-VIRTUAL B-ALLOCS C-JOB INFO D-MODULES *-REGION F-SUBPOOL G-TCBS
> H-LSQA
===============================================================================
> REGION AND PROGRAM INFORMATION
PEEK DA41MSTR ASID=225, collected at 11:18:28
step Job Step Pgm: DSNYASCP; 69 TCBs, 10 Datasets, and 94 Modules
+ Step started at 14:43:32 , now in step # 1 of 1
+
+ For the region below the 16M line:
+
+ Total private region = 9192K Unused = 8808K
+ Region requested = 0K Region limit = 9192K
+ Low PVT in use = 60K Unallocated = 24K Free = 7K
+ High PVT in use = 324K Unallocated = 4K Free = 78K
+ Start of SYSREG: 00002000 End of SYSREG: 00005FFF
+ Start of low PVT: 00006000 End of low PVT: 0001AFFF
+ Current top: 0001AFFF Limit of region: 008FFFFF
+ Start of high PVT: 008AE000 End of high PVT: 008FFFFF
+
+ For the extended region above the 16M line:
+
+ Total private region = 1559552K Unused = 1534964K
+ Region limit = 1559552K
+ Low PVT in use = 2304K Unallocated = 28K Free = 22K
+ High PVT in use = 22284K* Unallocated = 384K Free = 148K
+ *includes non-freemainable system area of 7480K starting at 7F800000
+ Start of low PVT: 20D00000 End of low PVT: 20F46FFF
+ Current top: 20F46FFF Limit of region: 7FFFFFFF
+ Start of high PVT: 7E9DD000 End of high PVT: 7FFFFFFF
===============================================================================
This panel requires special authorization because its use causes additional system overhead to collect the necessary data. Type /PWD on the top line of the panel, enter a valid password when requested, then press Enter. Thereafter, OMEGAMON® XE for Db2 PE displays the requested information.
Navigation
For additional
information about
- related topics, select one of the options at the top of the panel.
- other topics, use the PF keys.
Fields
- DA41MSTR
- The name of the job running in this address space. (In this case, DA41MSTR.)
- ASID
- The address space identification number.
- collected at
- The time at which OMEGAMON XE for Db2 PE collected the information for this address space.
- Job Step Pgm
- The name of the job step program currently executing.
- TCBs
- The number of TCBs currently attached.
- Datasets
- The number of data sets currently in use.
- Modules
- The number of modules currently in use.
- Step started at
- The time the current step started executing.
- now in step # n of m
- The number of the current step and the total number of steps in the job.
Each of the following fields is displayed twice:
once to describe the region below the 16 MB line and once to describe
the region above that line.
- Total private region
- The total size of the private area, including areas that cannot be allocated.
- Unused
- The amount of the total private area not currently in use.
- Region requested
- The amount specified on the REGION JCL parameter.
- Region limit
- The region limit that the IEALIMIT exit imposes.
- Low PVT in use
- The storage that the REGION parameter limits. This includes all of the user subpools.
- Unallocated
- The storage not allocated to subpools.
- Free
- The storage allocated to subpools but not currently GETMAINed.
- High PVT in use
- Includes LSQA, SWA, and subpools 229 and 230. This value is allocated from the top of the user's region downward and is not limited by the REGION JCL parameter.
- Start of SYSREG
- The beginning address of the area of storage reserved for use by the region control task.
- End of SYSREG
- The ending address of the area of storage reserved for use by the region control task.
- Start of low PVT
- The beginning address of the storage that the REGION parameter limits.
- End of low PVT
- The ending address of the storage that the REGION parameter limits.
- Current top
- The highest allocated address in the low PVT area at the current time.
- Limit of region
- The ending address of the low PVT area.
- Start of high PVT
- The beginning address of the high PVT area.
- End of high PVT
- The ending address of the high PVT area.