KD2_PFnn_HIS_SEQLOG1

The KD2_PFnn_HIS_SEQLOG1 parameter specifies names for up to 7 sequential data sets that will be created for trace data collection.

Description

A minimum of 2 data sets is required. Ensure that the set of historical sequential data sets is unique for each DB2 subsystem.

This field is only applicable if the storage type is VSAMSEQ, VSAMSEQTHVSAM, or SEQTHVSAM and the storage mechanism is STATIC SEQUENTIAL.

Required or optional
Optional (Required if KD2_PF_HIS_START is set to C,Y and KD2_PF_HIS_SEQ_TYP is set to S)
Default value
None
Locations where the parameter value is stored
Location 1
In the ALLOCDS member of the %RTE_HILEV%.%RTE_NAME%.RKD2SAM library
Output line
LISTCAT ENTRIES('<value>') NAME
Location 2
In the ALLOCDS member of the %RTE_HILEV%.%RTE_NAME%.RKD2SAM library
Output line
ALLOC DSNAME('<value>') -
PARMGEN name
KD2_PFnn_HIS_SEQLOG1
PARMGEN classification
NTH