KD2_PFnn_HIS_BUFSIZE
Data collection buffer size
- Description
-
Specifies the parameter that controls the size of the buffer, which is used to hold IFI records until they can be written out to the log dataset by the Near-Term History Data Collector. This value is specified in kilobytes.
- Required or optional
- Optional (Required in case KD2_PF_HIS_START is set to Y)
- Default value
- 1024
- Minimum
- 50
- Maximum
- 9999
- Location where the parameter value is stored
- In the COPTssid member of the rhilev.midlev.rtename.RKD2PAR library
- Output line
-
BUFSIZE(<value>)
- In the Configuration Tool (ICAT)
-
- Panel name
- Near-Term History
- Panel ID
- KD261P8
- Panel field
- Buffer size
- Default value
- 1024
- Minimum
- 50
- Maximum
- 9999
- Batch parameter name
- KD2_PF_HIS_BUFSIZE
- PARMGEN name
- KD2_PFnn_HIS_BUFSIZE
- PARMGEN classification
- NTH