Set XLF Printer and Routing Options

Use this panel to set options that control how the Exception Logging Facility logs exception messages.

Note: If you selected option E (ASF Options) from the Exception Logging Menu, a panel very similar to this one is displayed. The option settings on the Set ASF Printer and Routing Options panel reflect the settings on the Set Printer and Routing Options panel (see Set Printer and Routing Options). That is, there are two sets of options: one for exception logging (XLF) and one for all other output logging (including ASF).

________________ ZXLFOPT  VTM     O2       V540.#P DA41 11/06/13 11:34:07   2  
>       Help PF1           Back PF3           Up PF7           Down PF8         
> P.I.A                                                                         
=============================================================================== 
>                   SET XLF PRINTER AND ROUTING OPTIONS                         
                                                                                
> To change an option, type the new value to the right of the option name and   
> press ENTER.  The new value appears in the Pending column.  To make the value 
> the Current value, remove the > preceding .XLFOUT and press ENTER.            
                                                                                
>.XLFOUT                                                                        
 OUTP  XLFLOG                                                                   
+                           |----- Pending ------|----- Current ------|         
 copy                       | 1                  | 1                  |         
 ddnm                       | (*DYNAMIC)         | (*DYNAMIC)         |         
 dest                       | *NONE*             | *NONE*             |         
 dstu                       | *None*             | *None*             |         
 fold                       | YES                | YES                |         
 form                       | *None*             | *None*             |         
 hold                       | NO                 | NO                 |         
 id1                        | 'USER    '         | 'USER    '         |         
 id2                        | '                ' | '                ' |         
 id3                        | '                ' | '                ' |         
 id4                        | '                ' | '                ' |         
 lnct                       | 60                 | 60                 |         
 sout                       | A                  | A                  |         
=============================================================================== 

Navigation

For additional options, use the PF keys.

Fields

To modify an option, move the cursor between the name of the setting you want to change and the Pending column, type the new value, and press Enter. To save your changes, delete the comment character (>) next to .XLFOUT and press Enter. This releases the current log, moves the Pending values to the Current column, and reallocates the log using the new values.

Note: When a value is displayed within parentheses, it means that the field is inactive.
.XLFOUT
Prints the current log and leaves it open. OMEGAMON XE for DB2 PE places a comment character in front of .XLFOUT so that the log is reset only on cycles when you remove the comment character (>).
copy
The number of copies to print.
ddnm
Overrides the standard OMEGAMON XE for DB2 PE ddname. When ddnm is active, sout and its related parameters (copy, dest, dstu, form, and hold) are inactive. The ddname must be allocated within the O2CI started task JCL.
dest
The destination to receive the report. The default is NONE, which sends the output to the local printer. The device can be a terminal, a node, a remote workstation, a local device or group of devices, or a user ID.
dstu
The destination user ID to receive the report.
fold
Changes lowercase characters to uppercase. The default is YES.
form
The name of the form on which to print. The default is NONE. This means that OMEGAMON XE for Db2 PE uses the form defined as your installation's default. If you change NONE to some other value (such as HOLE), you can type an asterisk (*) to return to NONE.
hold
Specifies that the output be placed in the hold queue. The default is NO.
id1
Requests separator pages and page headers that identify output from different OMEGAMON XE for Db2 PE sessions.
id2
Defines up to 16 characters to be shown on the left of the separator page, justified below the ID1 heading. ID1 must be set to use ID2.
id3
Defines up to 16 characters to be shown centered on the separator page, below the ID1 heading. ID1 must be set to use ID3.
id4
Defines up to 16 characters to be shown on the right of the separator page, justified below the ID1 heading. ID1 must be set to use ID4.
lnct
Sets the XLFLOG file line count. The default is 60 lines.
sout
Specifies the SYSOUT class for the output.