If you have already installed Netcool®/OMNIbus, the
Netcool/OMNIbus
Knowledge Library, and the Probe for SNMP, you can now install Network Manager, and do not need
to follow the steps in this task. The Network Manager installer
configures Netcool/OMNIbus for you
during the installation process. If the ObjectServer setup changes after you have already installed
and configured Network Manager and Netcool/OMNIbus, then you
must reintegrate the ObjectServer with Network Manager as described in
this topic.
To reintegrate the Network Manager product
with the existing Tivoli® Netcool/OMNIbus V8.1
ObjectServer, run the ConfigOMNI script against
the ObjectServer.
Procedure
- Use the ConfigOMNI script
to configure an ObjectServer to run with Network Manager.
The script creates the Network Manager triggers
and GUI account information. If the ObjectServer is on a remote server,
then copy the $NCHOME/precision/install/scripts/ConfigOMNI script
and the support script $NCHOME/precision/scripts/create_itnm_triggers.sql and
put them into the same directory on the remote ObjectServer. If the
ObjectServer is local to Network Manager,
then you can use both scripts as is.
- On the
ObjectServer host, change to the scripts directory
and run the ConfigOMNI script.
For
example, the following configures the ObjectServer called NCOMS2
using
the administrative password NC0M5password
, or creates
the ObjectServer called NCOMS2
if it does not exist,
in the specified directory (OMNIHOME), and creates or modifies the itnmadmin
and itnmuser
users
in the ObjectServer.
./ConfigOMNI -o NCOMS2 -p NC0M5password -h /opt/ibm/tivoli/netcool -u ITNMpassword
-
You might also need to update the Network Manager core settings and the Web GUI data source settings.
For more information, see the Network Manager documentation https://www.ibm.com/docs/en/SSSHRK_4.2.0/install/task/ins_installingandconfiguringomnibus.html.