Obtain and install the Netcool®/OMNIbus core
components, Netcool/Impact,
and the Gateway for JDBC and Gateway for Message Bus.
All these products are installed by IBM® Installation
Manager.
You can use IBM Installation
Manager to
download the installation packages for these products and install
them in a single flow. Extra configuration of each product is required
after installation.
Procedure
-
Install the Netcool/OMNIbus
8.1.0.28
core components.
After the installation, you can use the Initial Configuration Wizard
(nco_icw) to configure the product, for example, create and start ObjectServers,
and configure automated failover or a multitier architecture. See related links later for
instructions on installing Netcool/OMNIbus.
- Install the Netcool/Impact GUI
server and Impact server. See related links later for instructions on installing Netcool/Impact.
-
Apply the latest supported Netcool/OMNIbus core and
Netcool/Impact
fix packs. Also ensure that you apply the appropriate IBM
Tivoli®
Netcool/Impact Server Extensions for Netcool Operations Insight® feature. This is delivered in the Netcool/Impact fix
pack.
For information on the product and component versions supported in the current version of
Netcool Operations Insight
including supported fix packs, see
On-premises components.
The IBM
Tivoli
Netcool/Impact Server Extensions for Netcool Operations Insight feature is required for the event analytics capability. Fix packs are available from
IBM Fix Central, see
http://www.ibm.com/support/fixcentral/
.
- Create the connection from Netcool/Impact to the
Db2® database as described in Configuring Db2 database connection within Netcool/Impact.
- Configure the ObjectServer to support the related events function of the event analytics
capability.
This requires a ParentIdentifier column in the alerts.status table.
- Configure the ObjectServer to support the topology search
capability. In $NCHOME/omnibus/extensions,
run the nco_sql utility against the scala_itnm_configuration.sql file.
./nco_sql -user root -password myp4ss -server NCOMS < /opt/IBM/tivoli/netcool/omnibus/extensions/scala/scala_itnm_configuration.sql
Triggers
are applied to the ObjectServer that delay the storage of events until
the events are enriched by Network Manager
IP Edition data
from the NCIM database.
- Install the Gateway for JDBC and
Gateway for Message Bus.
After installation, create the connection between the ObjectServer and the gateways in the
Server Editor (nco_xigen). See related links later for instructions on creating
connections in the Server Editor.
What to do next
Search on IBM Fix Central for
available interim fixes and apply them. See http://www.ibm.com/support/fixcentral/
.