Incomplete, stopped, and uninitiated configurations
Configuration run operations do not complete, are stalled on the Configure Analytics window, or fail to start.
Problem
Configuration run operations do not complete, are stalled on the Configure Analytics window, or fail to start.
Cause
These problems occur if the services are not started after Event Analytics is installed, or the Netcool®/Impact server is restarted.
Resolution
To resolve these problems, complete the following steps.
- In the Netcool/Impact UI, select the Impact Services tab.
- Ensure that each of the following services is started. To start a service, right-click the
service and select Start.
LoadRelatedEventPatterns
ProcessClosedPatternInstances
ProcessRelatedEventConfig
ProcessRelatedEventPatterns
ProcessRelatedEventTypes
ProcessRelatedEvents
ProcessSeasonalityAfterAction
ProcessSeasonalityConfig
ProcessSeasonalityEvents
ProcessSeasonalityNonOccurrence
UpdateSeasonalityExpiredRules