Default Netcool/OMNIbus users
When you run the database initialization utility (nco_dbinit) to create an ObjectServer, a set of default users is created.
The following table describes the default users, which are defined in
the security.sql script.
Username | Description |
---|---|
root |
This user is created with an empty string as a password by default. You can reset the password by using Netcool®/OMNIbus Administrator, or the ALTER USER ObjectServer SQL command. |
nobody |
This user is disabled and cannot be used to access the ObjectServer. Ownership
of each alert in the alerts.status table is assigned to a user when the row is
inserted. By default, probes assign rows to the nobody user. |
The permissions that are assigned to the default users are shown in the following table.
Permission | User root | User nobody |
---|---|---|
Set enable or disable. | No | No |
Set full name | Yes | No |
Set a password | Yes | No |
Set PAM | Yes | No |
Assign or remove restriction filter. | Yes | Yes Note: However, you cannot log on as a nobody user.
|
Drop user | No | No |
Grant or revoke permission. | No | No |
Be a member of a group. | Yes | Yes |