Testing Netcool/OMNIbus communication with IBM Maximo IT
This topic describes how to verify that Netcool/OMNIbus is successfully communicating with IBM Maximo IT.
Note: The gateway does not support resynchronization.
That means that you can only submit a request for a ticket to be created
while the gateway is running. If you submit the request while the
gateway is not running, you will have to resubmit the request after
you have restarted the gateway.
To confirm that Netcool/OMNIbus is successfully communicating with IBM Maximo IT, use the
following steps:
- Start the gateway.
- Start the Netcool/OMNIbus Events List.
- Right-click on an event.
- Set the LogTicket field to 1.
When the incident has been created within IBM Maximo IT, a
TTNumberis assigned (this is the incident number within IBM Maximo IT) and the TicketStatus field in the Event List is set to NEW. - To verify that a change to the incident's status is routed back to the Event List, change
the status of the ticket in IBM Maximo IT to
In Progressusing the Change Status dialog box.When the gateway next polls IBM Maximo IT, the updated status will be passed back to the ObjectServer and will appear in the Event List as INPROG.
- To verify that journal entries you create for events linked to IBM Maximo IT incidents result in
the creation of corresponding work logs in IBM Maximo IT, create a journal entry as shown
below.
When you check the incident in IBM Maximo IT , the work log is visible in the Work Logs tab.